RAMS NL-2301: Swap the lecture theatre microphones
Demo template. A demo template, not professional safety advice. A competent person must check every RAMS against the site, the work and the law where it happens before anyone relies on it.
Generated from the record, reviewed by Sam Okafor
- Client
- Fenwater Health
- Site
- Cambridge clinic, Lecture theatre
- When
- Wed 30 Sep
- Crew
- Ava Morales, Leo Hart
- For
- FW-INC-2201 · visit at risk
- Generated
- 24 Sep 2026, 15:40
The work, and what the record says
- Fit ceiling microphones · Listed on the job, 2 × Poly IP Ceiling Microphone
- Run and terminate cable · Listed on the job, 1 × Cat 6A cable, 305 m box
- Work in the comms room · Cables end in The IDF on level 1, with Fenwater estates
- Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): ceiling 6.2 m
- Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): raked seating; a mobile platform on the flat floor at the front reaches the ceiling
- Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): comms in the IDF on level 1, with Fenwater estates
- Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): a clinical education building, in use during the day
- Fenwater Health: Above-ceiling permit with infection control, issued 25 Sep
Risk after controls
Likelihood up, 1 rare to 5 almost certainSeverity across, 1 to 5
Low, 1 to 4Medium, 5 to 12High, 15 and above
Before controls: 1 high, 6 medium, 0 low.
Hazards and controls
H1Working at height
Work above 2 m: ceiling microphones at 6.2 m and cable through the ceiling at 6.2 m.
- Who might be harmed
- The crew; Patients, staff and visitors below (dropped tools)
- Controls
- A mobile elevating work platform (MEWP): above 3.5 m podium steps do not reach
- Only people with in-date working at height training work above 2 m
- The area below kept clear with barriers and a sign
- Tools on lanyards; nothing loose on the platform
Source: Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): ceiling 6.2 m. Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): ceiling 6.2 m
Before High · 3 × 5After Medium · 1 × 5H2Operating a mobile platform
The ceiling is 6.2 m high: the platform could tip, trap or strike someone. Raked seating; a mobile platform on the flat floor at the front reaches the ceiling.
- Who might be harmed
- The crew; Patients, staff and visitors
- Controls
- An IPAF-trained operator, with a second person on the ground throughout
- Outriggers set on the flat floor only, checked before each lift
- The platform area fenced off while it moves
Source: Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): ceiling 6.2 m. Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): raked seating; a mobile platform on the flat floor at the front reaches the ceiling
Before Medium · 2 × 5After Medium · 1 × 5H3Hidden cables and pipes when drilling
Fixings for mounts and brackets go into walls or ceilings that may hide power cables or pipes.
- Who might be harmed
- The crew; Patients, staff and visitors
- Controls
- A cable and pipe detector over every fixing point before drilling
- Fixings only where the client's drawings or the site contact confirm it is clear
- Stop and report anything unexpected
Source: Tasks: fit ceiling microphones (Listed on the job, 2 × Poly IP Ceiling Microphone)
Before Medium · 2 × 4After Low · 1 × 4H4Work beside live equipment in the comms room
The IDF on level 1, with Fenwater estates: patching beside switches that carry the building's network.
- Who might be harmed
- The crew; Everyone on the client's network (an outage)
- Controls
- Access approved by the client; the rack left as found
- Only the ports on the job touched; live patching never moved
- No food or drink in the room
Source: Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): comms in the IDF on level 1, with Fenwater estates
Before Medium · 2 × 3After Low · 1 × 3H5Working near patients
A clinical education building, in use during the day: patients, staff and visitors pass close to the work.
- Who might be harmed
- Patients, staff and visitors
- Controls
- Barriers and signs round the work area
- Noisy work and drilling booked with the site contact, out of hours where possible
- Corridors and doors kept clear; cables never left across a walkway
Source: Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): a clinical education building, in use during the day
Before Medium · 3 × 3After Low · 1 × 3H6Dust from the ceiling void
Opening ceiling tiles near clinical areas can release dust and spores.
- Who might be harmed
- Patients; Staff
- Controls
- The client's above-ceiling permit with infection control, before any tile is lifted
- Dust sheets and a HEPA vacuum; tiles back the same day
- Work in the order infection control sets
Source: Northlight's survey (Lecture theatre, 12 Sep 2026, Sam Okafor): a clinical education building, in use during the day. Fenwater Health: Above-ceiling permit with infection control, issued 25 Sep
Before Medium · 3 × 4After Low · 1 × 4H7Trips over cable, cuts from tray edges
Cable pulled across floors and through tray and ceiling grid with sharp edges.
- Who might be harmed
- The crew; Patients, staff and visitors
- Controls
- Cable pulled in one run and dressed away at once
- Gloves when handling tray and ceiling grid
- Offcuts and packaging cleared as the work goes
Source: Task: run and terminate cable (Listed on the job, 1 × Cat 6A cable, 305 m box)
Before Medium · 3 × 2After Low · 1 × 2
Method statement
- Before the visit. This RAMS approved and briefed to the crew; badges, induction and access confirmed; kit reserved and loaded.
- Arrive and sign in. Sign in with Fenwater Health's site contact; agree the work area and any times to avoid. (H5)
- Set up the work area. Barriers and signs round the area; floor protection where kit is moved. (H5)
- Run the cable. From the platform at 6.2 m; dressed away as it goes; ceiling tiles back the same day. (H1, H6, H7)
- Fit the ceiling microphones. From the platform, with a ground person; tiles and grid handled with gloves. (H1, H2, H6)
- Patch in the comms room. Only the job's ports; fire stopping checked and photographed before leaving. (H4)
- Configure and test. Each unit set up from its setup guide; the room test run and recorded on the job.
- Clear up and hand back. Waste and packaging removed; the area handed back to the site contact; the as-built recorded on the job.
Personal protective equipment
- Safety boots
- Gloves
- Eye protection when drilling
- Dust mask when drilling or in the ceiling void
- Harness and lanyard on the platform
Emergency arrangements
- First aider on the crew: Ava Morales
- Internal emergency line 2222 from any hospital phone; fire assembly point in car park B
- Emergency services: 911
- Report any incident to Fenwater Health's site contact and to Northlight's safety lead the same day
Competence: the crew's certifications
- Working at height, everyone on the visitWork above 2 m. In date on Wed 30 Sep.
- IPAF, at least one personA mobile platform for the 6.2 m ceiling. In date on Wed 30 Sep.
- CTS, at least one personConfigure and test to the setup guides. In date on Wed 30 Sep.
Certifications from Northlight's crew record (Ava Morales, Leo Hart), checked on the last day of the work. 9 kinds are tracked, from CTS to site safety cards.
Review and sign-off
- Reviewer's note: Bring the tall ladder as a spare for the side aisles (crew note, 26 Sep).
| Briefed to | Role | Signature | Date |
|---|---|---|---|
| Ava Morales | Resident technician | ||
| Leo Hart | Installer |