RAMS NL-2318: Juneau fit-out: Wren 2.03 and the flex desks 2.07
Demo template. A demo template, not professional safety advice. A competent person must check every RAMS against the site, the work and the law where it happens before anyone relies on it.
Generated from the record, waiting for review
- Client
- Aigna
- Site
- Juneau office, 2.03 Wren, 2.07 Flex desks A
- When
- Mon 5 Oct to Wed 7 Oct
- Crew
- Sam Okafor, Leo Hart, Maya Brooks
- For
- PRJ-14 · visit at risk
- Generated
- 28 Sep 2026, 09:00
The work, and what the record says
- Configure and test · Listed on the job
- Mount displays on the wall · 1 × Display, 43 in, for huddle rooms
- Run and terminate cable · 1 × Display, 43 in, for huddle rooms, 1 × Logitech MeetUp 2, 1 × Cat 6A cable, 305 m box
- Wall-mount a camera or video bar · 1 × Logitech MeetUp 2
- Set up desk monitors · 8 × Dell UltraSharp 27 Thunderbolt Hub Monitor (U2724DE)
- Work in the comms room · Cables end in 2.08 Comms room (MDF)
- Electrical work by others · Power and data at the display walls by Aigna's facilities team (T-1403, done by 31 Jul 2026)
- Aigna's floor record: ceiling 2.7 m (Juneau office, second floor), shared on this job
- Aigna's floor record: cable tray in the corridor ceiling at 3.1 m (Juneau office, second floor)
- Aigna's record: 2.08 Comms room (MDF). Comms room in the core, beside riser 1; the riser cupboard opens into it. The same place on every floor
- Aigna's floor record: Riser 1 (data), fire-stopped at each floor
- Aigna's project PRJ-14: a fit-out, not yet open (handover target 16 Oct 2026)
- Aigna's project PRJ-14, task T-1403
Risk after controls
Likelihood up, 1 rare to 5 almost certainSeverity across, 1 to 5
Low, 1 to 4Medium, 5 to 12High, 15 and above
Before controls: 1 high, 7 medium, 0 low.
Hazards and controls
H1Working at height
Work above 2 m: cable tray at 3.1 m.
- Who might be harmed
- The crew; Other trades on site below (dropped tools)
- Controls
- Podium steps with guard rails; a leaning ladder only for short access
- Only people with in-date working at height training work above 2 m
- The area below kept clear with barriers and a sign
- Tools on lanyards; nothing loose on the platform
Source: Aigna's floor record: cable tray in the corridor ceiling at 3.1 m (Juneau office, second floor)
Before High · 3 × 5After Medium · 1 × 5H2Lifting and carrying
Displays lifted onto wall mounts; 8 monitors carried in their boxes.
- Who might be harmed
- The crew
- Controls
- Two people for every display lift
- A trolley from the lift to the space; boxes opened where the kit is fitted
- Clear route agreed before moving kit
Source: Display, 43 in, for huddle rooms: no weight in the device library, so treated as a two-person lift. Dell UltraSharp 27 Thunderbolt Hub Monitor (U2724DE): 5.23 kg each, 8 of them (device library)
Before Medium · 3 × 3After Low · 2 × 2H3Hidden cables and pipes when drilling
Fixings for mounts and brackets go into walls or ceilings that may hide power cables or pipes.
- Who might be harmed
- The crew; Other trades on site
- Controls
- A cable and pipe detector over every fixing point before drilling
- Fixings only where the client's drawings or the site contact confirm it is clear
- Stop and report anything unexpected
Source: Tasks: mount displays on the wall (1 × Display, 43 in, for huddle rooms); Tasks: wall-mount a camera or video bar (1 × Logitech MeetUp 2)
Before Medium · 2 × 4After Low · 1 × 4H4Electrical work by others
Power and data at the display walls by Aigna's facilities team (T-1403, done by 31 Jul 2026). Northlight fits plug-in and low-voltage kit only.
- Who might be harmed
- The crew
- Controls
- No work on fixed wiring: only the client's electrician opens a socket or a board
- Every outlet checked with a socket tester before kit is plugged in
- Faults reported to the site contact, never fixed by the crew
Source: Aigna's project PRJ-14, task T-1403
Before Medium · 2 × 5After Medium · 1 × 5H5Work beside live equipment in the comms room
2.08 Comms room (MDF): patching beside switches that carry the building's network.
- Who might be harmed
- The crew; Everyone on the client's network (an outage)
- Controls
- Access approved by the client; the rack left as found
- Only the ports on the job touched; live patching never moved
- No food or drink in the room
Source: Aigna's record: 2.08 Comms room (MDF). Comms room in the core, beside riser 1; the riser cupboard opens into it. The same place on every floor
Before Medium · 2 × 3After Low · 1 × 3H6Fire stopping in the riser
Riser 1 (data) opens into the comms room; fire-stopped at each floor. A cable through it could break the fire stopping.
- Who might be harmed
- Everyone on site
- Controls
- No new cable through the riser without the client's permit
- Any fire stopping disturbed is made good the same day and photographed
- The photo goes on the as-built
Source: Aigna's floor record: Riser 1 (data), fire-stopped at each floor
Before Medium · 2 × 5After Medium · 1 × 5H7Other trades on an active fit-out
The office is still a construction site: other trades, open floors and moving materials.
- Who might be harmed
- The crew; Other trades
- Controls
- Site induction before work; the site manager's rules and permits followed
- Hard hat, high-visibility vest and safety boots on the floor
- A site safety card for everyone on the crew
Source: Aigna's project PRJ-14: a fit-out, not yet open (handover target 16 Oct 2026)
Before Medium · 3 × 4After Medium · 2 × 3H8Trips over cable, cuts from tray edges
Cable pulled across floors and through tray and ceiling grid with sharp edges.
- Who might be harmed
- The crew; Other trades on site
- Controls
- Cable pulled in one run and dressed away at once
- Gloves when handling tray and ceiling grid
- Offcuts and packaging cleared as the work goes
Source: Task: run and terminate cable (1 × Display, 43 in, for huddle rooms, 1 × Logitech MeetUp 2, 1 × Cat 6A cable, 305 m box)
Before Medium · 3 × 2After Low · 1 × 2
Method statement
- Before the visit. This RAMS approved and briefed to the crew; badges, induction and access confirmed; kit reserved and loaded.
- Arrive and sign in. Sign in with Aigna's site contact and the site manager; agree the work area and any times to avoid. (H7)
- Set up the work area. Mark the work area; check the route in for other trades' materials. (H7)
- Bring the kit in. Trolley from the lift; two people for every display; boxes opened where the kit is fitted. (H2)
- Run the cable. From podium steps at 3.1 m; dressed away as it goes. (H1, H8)
- Mount the kit. Detector over each fixing point, then the mount; the display lifted on by two people and locked. (H2, H3)
- Set up the desk monitors. Each monitor on its arm or stand, cabled to the dock, tested at the desk. (H2)
- Patch in the comms room. Only the job's ports; fire stopping checked and photographed before leaving. (H5, H6)
- Configure and test. Each unit set up from its setup guide; the room test run and recorded on the job.
- Clear up and hand back. Waste and packaging removed; the area handed back to the site contact; the as-built recorded on the job.
Personal protective equipment
- Safety boots
- Hard hat
- High-visibility vest
- Gloves
- Eye protection when drilling
- Dust mask when drilling or in the ceiling void
Emergency arrangements
- First aider on the crew: Sam Okafor
- The site's fire alarm, assembly point and first aiders: confirmed at induction (not in the record)
- Emergency services: 911
- Report any incident to Aigna's site contact and to Northlight's safety lead the same day
Competence: the crew's certifications
- Working at height, everyone on the visitWork above 2 m. Working at height for Maya expired 15 Sep.
- Site safety card, everyone on the visitAn active fit-out site. In date on Wed 7 Oct.
- CTS, at least one personConfigure and test to the setup guides. In date on Wed 7 Oct.
Certifications from Northlight's crew record (Sam Okafor, Leo Hart, Maya Brooks), checked on the last day of the work. 9 kinds are tracked, from CTS to site safety cards.
Review and sign-off
| Briefed to | Role | Signature | Date |
|---|---|---|---|
| Sam Okafor | Project engineer | ||
| Leo Hart | Installer | ||
| Maya Brooks | AV engineer |