SwitchSIN12.08 Comms room (MDF), Rack 1, U13Meraki dashboard · read 06:00Simulated
sin-1208-as01
26 ports in use, each on the VLAN the plan gives itchecked just now
The ports
Cisco Catalyst 9300-48P · 50 portsPorts 49 to 50 · uplinks
- 10 Management
- 20 Corporate
- 30 Room systems
- 31 Displays and signage
- 70 Printers
- T Trunk: several VLANs, tagged
- X 802.1X · M MAC check (MAB)
- P Parked: patched, nothing plugged in
- – Disabled: nothing patched
Restricted: rack and switch ports Recorded for the demo, as Meraki dashboard would report it. Select a port to open what is plugged into it.
Change VLAN
Every port in use
26 in uses, 16 parked, 8 disabled| Port | On it | Mode | VLAN | Plan | Change |
|---|---|---|---|---|---|
| Port 1 | Display 1 · sin-1201-dsp0112.01 Kestrel · Wall outlet A1 · Patch panel port 1 | AccessMAC check (MAB) | Planned VLAN 31 Displays and signage | As planned | |
| Port 2 | Video bar · sin-1201-vc0112.01 Kestrel · Wall outlet A2 · Patch panel port 2 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 3 | Display 2 · sin-1201-dsp0212.01 Kestrel · Wall outlet B3 · Patch panel port 3 | AccessMAC check (MAB) | Planned VLAN 31 Displays and signage | As planned | |
| Port 4 | Nothing plugged in12.01 Kestrel · Wall outlet B4 · Patch panel port 4 | Shut | Parked | Parked | |
| Port 5 | Touch controller · sin-1201-tc0112.01 Kestrel · Floor box C1 · Patch panel port 5 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 6 | Nothing plugged in12.01 Kestrel · Floor box C2 · Patch panel port 6 | Shut | Parked | Parked | |
| Port 7 | Nothing plugged in12.01 Kestrel · Wall outlet E1 · Patch panel port 7 | Shut | Parked | Parked | |
| Port 8 | Display · sin-1202-dsp0112.02 Heron · Wall outlet A1 · Patch panel port 8 | AccessMAC check (MAB) | Planned VLAN 31 Displays and signage | As planned | |
| Port 9 | Video bar · sin-1202-vc0112.02 Heron · Wall outlet A2 · Patch panel port 9 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 10 | Nothing plugged in12.02 Heron · Wall outlet A3 · Patch panel port 10 | Shut | Parked | Parked | |
| Port 11 | Nothing plugged in12.02 Heron · Wall outlet A4 · Patch panel port 11 | Shut | Parked | Parked | |
| Port 12 | Touch controller · sin-1202-tc0112.02 Heron · Floor box B1 · Patch panel port 12 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 13 | Nothing plugged in12.02 Heron · Floor box B2 · Patch panel port 13 | Shut | Parked | Parked | |
| Port 14 | Nothing plugged in12.02 Heron · Wall outlet D1 · Patch panel port 14 | Shut | Parked | Parked | |
| Port 15 | Display 1 · sin-1203-dsp0112.03 Curlew · Wall outlet A1 · Patch panel port 15 | AccessMAC check (MAB) | Planned VLAN 31 Displays and signage | As planned | |
| Port 16 | In-room network switch · sin-1203-sw0112.03 Curlew · Wall outlet A2 · Patch panel port 16 | Trunk, tagged 30 | Planned VLAN 10 Management | As planned | |
| Port 17 | Nothing plugged in12.03 Curlew · Wall outlet A3 · Patch panel port 17 | Shut | Parked | Parked | |
| Port 18 | Display 2 · sin-1203-dsp0212.03 Curlew · Wall outlet B4 · Patch panel port 18 | AccessMAC check (MAB) | Planned VLAN 31 Displays and signage | As planned | |
| Port 19 | Video bar · sin-1203-vc0112.03 Curlew · Wall outlet B5 · Patch panel port 19 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 20 | Touch controller · sin-1203-tc0112.03 Curlew · Floor box C1 · Patch panel port 20 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 21 | Nothing plugged in12.03 Curlew · Floor box C2 · Patch panel port 21 | Shut | Parked | Parked | |
| Port 22 | Nothing plugged in12.03 Curlew · Wall outlet D1 · Patch panel port 22 | Shut | Parked | Parked | |
| Port 23 | Display · sin-1204-dsp0112.04 Wren · Wall outlet A1 · Patch panel port 23 | AccessMAC check (MAB) | Planned VLAN 31 Displays and signage | As planned | |
| Port 24 | Video bar · sin-1204-vc0112.04 Wren · Wall outlet A2 · through the powers the video bar · Patch panel port 24 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 25 | Nothing plugged in12.04 Wren · Wall outlet A3 · Patch panel port 25 | Shut | Parked | Parked | |
| Port 26 | Nothing plugged in12.04 Wren · Wall outlet A4 · Patch panel port 26 | Shut | Parked | Parked | |
| Port 27 | Touch controller · sin-1204-tc0112.04 Wren · Floor box C1 · Patch panel port 27 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 28 | Nothing plugged in12.04 Wren · Floor box C2 · Patch panel port 28 | Shut | Parked | Parked | |
| Port 29 | Display · sin-1205-dsp0112.05 Robin · Wall outlet A1 · Patch panel port 29 | AccessMAC check (MAB) | Planned VLAN 31 Displays and signage | As planned | |
| Port 30 | Video bar · sin-1205-vc0112.05 Robin · Wall outlet A2 · through the powers the video bar · Patch panel port 30 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 31 | Nothing plugged in12.05 Robin · Wall outlet A3 · Patch panel port 31 | Shut | Parked | Parked | |
| Port 32 | Nothing plugged in12.05 Robin · Wall outlet A4 · Patch panel port 32 | Shut | Parked | Parked | |
| Port 33 | Touch controller · sin-1205-tc0112.05 Robin · Floor box C1 · Patch panel port 33 | AccessMAC check (MAB) | Planned VLAN 30 Room systems | As planned | |
| Port 34 | Nothing plugged in12.05 Robin · Floor box C2 · Patch panel port 34 | Shut | Parked | Parked | |
| Port 35 | Monitor12.06 Goldcrest · Desk module A1 · Patch panel port 35 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 36 | Printer · sin-1207-prn0112.07 Copy and print · Wall outlet A1 · Patch panel port 36 | AccessMAC check (MAB) | Planned VLAN 70 Printers | As planned | |
| Port 37 | Access point · sin-12-ap01Access point sin-12-ap01 · Ceiling jack above sin-12-ap01 · Patch panel port 37 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 38 | Access point · sin-12-ap02Access point sin-12-ap02 · Ceiling jack above sin-12-ap02 · Patch panel port 38 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 39 | Access point · sin-12-ap03Access point sin-12-ap03 · Ceiling jack above sin-12-ap03 · Patch panel port 39 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 40 | Access point · sin-12-ap04Access point sin-12-ap04 · Ceiling jack above sin-12-ap04 · Patch panel port 40 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 49 | Switch sin-1208-cs01 port 1Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned | |
| Port 50 | Switch sin-1208-cs02 port 1Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned |
Disabled, nothing patched: 41 to 48.
If this were off
SimulatedWhat this switch would cut off, worked out from the recorded patching. Press a port to narrow it.
Access switch Cisco Catalyst 9300-48P · Rack 1, U13 · 12.08 Comms room (MDF)
Would affect 7 spaces, 24 meetings in the next 24 hours (117 people) and 2 services
Twelfth floor
Restricted: rack and switch ports "Up" is an uplink: the way this switch reaches the internet.
Spaces it would cut off 7
- 12.01 KestrelFloor 12 · 4 units · 4 bookings
- 12.02 HeronFloor 12 · 3 units · 5 bookings
- 12.03 CurlewFloor 12 · 6 units · 7 bookings
- 12.04 WrenFloor 12 · 4 units · 2 bookings
- 12.05 RobinFloor 12 · 4 units · 3 bookings
- 12.06 GoldcrestFloor 12 · 1 unit · 3 bookings
- 12.07 Copy and printFloor 12 · 1 unit
- Wi-Fi in the open areas4 access points
As recorded
NetBox's namesThe switch's record, with every interface's cable trace
id: sin-1208-as01
rack: sin-12-08-r1
u: 13
platform: meraki
interfaces:
- name: 1
enabled: true
mode: access
untagged_vlan: 31
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P01
device: AG-001343
interface: lan-1
- name: 2
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P02
device: AG-001345
interface: lan-1
- name: 3
enabled: true
mode: access
untagged_vlan: 31
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P03
device: AG-001344
interface: lan-1
- name: 4
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P04
- name: 5
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P05
device: AG-001346
interface: lan-1
- name: 6
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P06
- name: 7
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P07
- name: 8
enabled: true
mode: access
untagged_vlan: 31
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P08
device: AG-001349
interface: lan-1
- name: 9
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P09
device: AG-001350
interface: lan-1
- name: 10
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P10
- name: 11
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P11
- name: 12
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P12
device: AG-001351
interface: lan-1
- name: 13
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P13
- name: 14
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P14
- name: 15
enabled: true
mode: access
untagged_vlan: 31
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P15
device: AG-001354
interface: lan-1
- name: 16
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 30
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P16
device: AG-001360
interface: lan-9
- name: 17
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P17
- name: 18
enabled: true
mode: access
untagged_vlan: 31
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P18
device: AG-001355
interface: lan-1
- name: 19
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P19
device: AG-001356
interface: lan-1
- name: 20
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P20
device: AG-001357
interface: lan-1
- name: 21
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P21
- name: 22
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P22
- name: 23
enabled: true
mode: access
untagged_vlan: 31
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P23
device: AG-001366
interface: lan-1
- name: 24
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P24
device: AG-001367
interface: lan-1
- name: 25
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P25
- name: 26
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P26
- name: 27
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P27
device: AG-001368
interface: lan-1
- name: 28
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P28
- name: 29
enabled: true
mode: access
untagged_vlan: 31
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P29
device: AG-001372
interface: lan-1
- name: 30
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P30
device: AG-001373
interface: lan-1
- name: 31
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P31
- name: 32
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P32
- name: 33
enabled: true
mode: access
untagged_vlan: 30
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P33
device: AG-001374
interface: lan-1
- name: 34
enabled: false
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P34
- name: 35
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P35
device: AG-001378
interface: lan-1
- name: 36
enabled: true
mode: access
untagged_vlan: 70
auth: mab
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P36
device: AG-001379
interface: lan-1
- name: 37
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P37
device: AG-003272
interface: lan-1
- name: 38
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P38
device: AG-003273
interface: lan-1
- name: 39
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P39
device: AG-003274
interface: lan-1
- name: 40
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- sin-cb-01
- SIN-12.08-R1-U14-P40
device: AG-003275
interface: lan-1
- name: 49
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- sin-cb-02
device: sin-1208-cs01
interface: 1
- name: 50
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- sin-cb-03
device: sin-1208-cs02
interface: 1
disabled: 41-48