Vendor access
This part is for Aigna staff
Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.
Go to your installationModule
Locations is switched off
Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.
Office · DublinSimulated live
Dublin office in 3D
Every copper run within 90 m · fullest tray at 74% of its limitchecked just now
- 41Spaces placed
- 349Cable runs
- 21Access points
- –Spaces with a problem
Hold Ctrl and scroll, or pinch, to zoom
Building the model
Choose with the keyboard on the floor plan Drag to turn, Shift-drag to move, Ctrl and scroll to zoom.
Fifth floor
- Meeting rooms
- Breakout
- Corridors
- Stairs
- Lifts
- Toilets
- Riser
- Comms room
- Stores and ducts
Fourth floor
- Meeting rooms
- Focus, huddle and offices
- Pantry and café
- Print and storage
- Flex desks
- Assigned desks
- Breakout
- Corridors
- Stairs
- Lifts
- Toilets
- Riser
- Comms room
- Stores and ducts
Third floor
- Meeting rooms
- Reception
- Pantry and café
- Print and storage
- Town hall
- Breakout
- Corridors
- Stairs
- Lifts
- Toilets
- Riser
- Comms room
- Stores and ducts
SpacesIn useFreeProblemClosedComms room
Cables by purposeUser dataAV and room systemsCritical and security systemsMultimode fibreInternet circuits
Cables by healthHealthyAlertDownSpare or not monitored
Simulated live: space states and device health from the live simulation, a new moment every five seconds. Cables are drawn thicker than life.
Restricted: building model Fictional floor plan: space sizes from the space types; layout, trays and cable lengths made up for the demo.
What the model holds
Fictional floor plan- Floors
- Third floor at 11.4 m, Fourth floor at 15.2 m, Fifth floor at 19 m; slab to slab 3.8 m, ceilings 2.7 m
- Comms rooms
- 3.21 Comms room (MDF), 42U; 4.21 Comms room (IDF), 42U; 5.21 Comms room (IDF), 42U
- Cable runs
- 349 permanent links (every data outlet, in use or spare, and every access point) and 2 riser fibre; longest copper run 63.2 m, within the 90 m limit
- Trays
- 83 lengths of ladder, tray and basket; the fullest is the south corridor tray, east on floor 3, at 74 percent of what it takes at the 40 percent fill limit
- Wi-Fi
- Third floor: 8 access points for 388 m² of open area and 112 m² of town hall; Fourth floor: 8 access points for 637 m² of open area; Fifth floor: 5 access points for 534 m² of open area
- The way in
- Carrier One (primary) from the south duct, 42 m of fibre; Carrier Two (secondary) from the north duct, 55 m of fibre. Both share riser 1 inside the building: one path, recorded as a risk.
Fictional floor plan: space sizes from the space types; layout, trays and cable lengths made up for the demo. Space sizes and shapes follow each space's space type, with the differences a real building has (a column, a door moved, a slightly different size). Lengths are measured along the trays, with 3 m of slack at the panel.