Vendor access
This part is for Aigna staff
Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.
Go to your installationModule
Locations is switched off
Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.
Office · New YorkSimulated live
New York office in 3D
Every copper run within 90 m · fullest tray at 78% of its limitchecked just now
- 60Spaces placed
- 509Cable runs
- 19Access points
- –Spaces with a problem
Hold Ctrl and scroll, or pinch, to zoom
Building the model
Choose with the keyboard on the floor plan Drag to turn, Shift-drag to move, Ctrl and scroll to zoom.
Level 22
- Meeting rooms
- Focus, huddle and offices
- Pantry and café
- Print and storage
- Flex desks
- Assigned desks
- Breakout
- Corridors
- Stairs
- Lifts
- Toilets
- Riser
- Comms room
- Stores and ducts
Level 21
- Meeting rooms
- Focus, huddle and offices
- Pantry and café
- Print and storage
- Flex desks
- Breakout
- Corridors
- Stairs
- Lifts
- Toilets
- Riser
- Comms room
- Stores and ducts
Level 20: welcome and meeting floor
- Meeting rooms
- Reception
- Pantry and café
- Print and storage
- Town hall
- Breakout
- Corridors
- Stairs
- Lifts
- Toilets
- Riser
- Comms room
- Stores and ducts
SpacesIn useFreeProblemClosedComms room
Cables by purposeUser dataAV and room systemsCritical and security systemsMultimode fibreInternet circuits
Cables by healthHealthyAlertDownSpare or not monitored
Simulated live: space states and device health from the live simulation, a new moment every five seconds. Cables are drawn thicker than life.
Restricted: building model Fictional floor plan: space sizes from the space types; layout, trays and cable lengths made up for the demo.
What the model holds
Fictional floor plan- Floors
- Level 20: welcome and meeting floor at 76 m, Level 21 at 79.8 m, Level 22 at 83.6 m; slab to slab 3.8 m, ceilings 2.7 m
- Comms rooms
- 20.14 Comms room (MDF), 42U; 21.23 Comms room (IDF), 42U; 22.22 Comms room (IDF), 42U
- Cable runs
- 509 permanent links (every data outlet, in use or spare, and every access point) and 2 riser fibre; longest copper run 54 m, within the 90 m limit
- Trays
- 100 lengths of ladder, tray and basket; the fullest is the south corridor tray, east on floor 21, at 78 percent of what it takes at the 40 percent fill limit
- Wi-Fi
- Level 20: welcome and meeting floor: 4 access points for 260 m² of open area and 102 m² of town hall; Level 21: 8 access points for 529 m² of open area; Level 22: 7 access points for 525 m² of open area
- The way in
- Carrier One (primary) from the south duct, 106 m of fibre; Carrier Two (secondary) from the north duct, 103 m of fibre. Both share riser 1 inside the building: one path, recorded as a risk.
Fictional floor plan: space sizes from the space types; layout, trays and cable lengths made up for the demo. Space sizes and shapes follow each space's space type, with the differences a real building has (a column, a door moved, a slightly different size). Lengths are measured along the trays, with 3 m of slack at the panel.