Build sheetBatch 5 of 8Project PRJ-15Simulated live
3.09 Whooper Swan av switcher
2 values not recorded yet · 10 settings to set, 14 to checkchecked just now
Asset register
Assetbox › Assets- Asset tagAssetbox › Assets
The install recordAG-000340CheckThis unitNot seen yet - Serial numberAssetbox › Assets
The install recordDEMO-DUB-000340CheckThis unitNot seen yet - ModelAssetbox › Assets
The space typeKramer SWT3-31-HUCheckEvery unitNot seen yet - LocationAssetbox › Assets
The spaceDublin office, 3.09 Whooper SwanSetThis unitNot seen yet
Routing
Routing / AV Settings pages- Auto-switching Selection ModeRouting / AV Settings pages › AV Settings › Auto switching
The setup guide, the same on every unitPriority, with the USB-C laptop input (Input 1) highestSetEvery unitConfirm by hand - USB Host RoutingRouting / AV Settings pages › Routing Settings › Routing Page
The setup guide, the same on every unitUSB follows AV coupled routingSetEvery unitConfirm by hand
Identity and network
Device web interface- Device NameDevice web interface › Device › General › General Preferences
Not recordedNo hostname in the install record yet. Give it one on the Deploy page first.
SetThis unitConfirm by hand - IP ModeDevice web interface › Device › General › Network
Leave it on DHCP (DHCP (default), with a reservation on the AV VLAN). The reservation gives it this address.Its DHCP reservation (simulated address plan)10.20.3.90CheckThis unitConfirm by hand
Control and time
Control Gateway / Device › General pages- Serial Port TunnelingControl Gateway / Device › General pages › Control Gateway › Serial Ports
The setup guide, the same on every unitControl (RS-232 controls the SWT3-31-HU itself)CheckEvery unitConfirm by hand - Use Time Server (NTP)Control Gateway / Device › General pages › Device › General › Time and Date
The setup guide, the same on every unitManualSetEvery unitConfirm by hand - Time server addressControl Gateway / Device › General pages › Device › General › Time and Date
The house time serversntp1.aigna.exampleSetEvery unitConfirm by hand - Sync frequencyControl Gateway / Device › General pages › Device › General › Time and Date
The setup guide, the same on every unit1 daySetEvery unitConfirm by hand
Firmware
Device › General page- Firmware update methodDevice › General page
The setup guide, the same on every unitManual upload only, no automatic-update toggle existsCheckEvery unitConfirm by hand
Security
Security page- Security StatusSecurity page › Security › Security
The setup guide, the same on every unitOn (default)CheckEvery unitConfirm by hand - Web Pages Access PasswordSecurity page › Security › Security
From the password vault,
The password vault. The secret itself is never shown here.Dublin office / AV / Kramer SWT3-31-HU / Web Pages Access PasswordSetThis unitConfirm by hand - 802.1X AuthenticationSecurity page › Security › 802.1X
The setup guide, the same on every unitOffSetEvery unitConfirm by hand
AV settings
AV Settings › Audio Video Settings page- HDCP (per input)AV Settings › Audio Video Settings page
The setup guide, the same on every unitYes (default) on all inputsCheckEvery unitConfirm by hand - HDCP (output)AV Settings › Audio Video Settings page
The setup guide, the same on every unitFollow Input (default)CheckEvery unitConfirm by hand - Color Depth Force 8BitsAV Settings › Audio Video Settings page
The setup guide, the same on every unitDisable (default)CheckEvery unitConfirm by hand - Force LPCM 2CHAV Settings › Audio Video Settings page
The setup guide, the same on every unitDisable (default)CheckEvery unitConfirm by hand - Force RGB on OutputAV Settings › Audio Video Settings page
The setup guide, the same on every unitDisable (default)CheckEvery unitConfirm by hand - Auto Sleep DelayAV Settings › Audio Video Settings page
The setup guide, the same on every unitEnabled (default)CheckEvery unitConfirm by hand - No input signal (sleep timeout)AV Settings › Audio Video Settings page
The setup guide, the same on every unit900 seconds (default)CheckEvery unitConfirm by hand - Analog output volumeAV Settings › Audio Video Settings page › Routing Settings › Analog Outputs
Not recordedDecided or measured on site, during setup or commissioning, so it is not recorded before. Note it on the unit afterwards.
SetThis unitConfirm by hand