Vendor access
This part is for Aigna staff
Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.
Go to your installationModule
Projects is switched off
Projects, the schedule, planning, the work plan and the Lab. This demo has the Projects module switched off in Organisation settings.
Batch 7 of 9 · Project PRJ-17Simulated live
2 Kramer VP-440H2 adapters
0 of 2 units set up · nothing to reviewchecked just now
Setup is done by Aigna's engineers. Your installs are on the Deploy page.
Once for all 2
Through Device web interfaceSet on each unit by hand Device web interface. Keia Atlas cannot read these back, so a person confirms them.
10 settings to set and 2 to check; 0 left at the manufacturer's default.See every settingThe setup guide
The same on every unit
- Web pages user name and password
- Vault: Copenhagen office / AV / Kramer VP-440H2 / Web pages user name and password
- EDID source for each input
- Copy the connected display's own EDID to every input
- IP MODE
- 10.90.4.218
- Authenticate Web Pages access
- On
- HDCP on inputs (HDBT, HDMI1-3)
- ON for every input
- HDCP on outputs (HDMI OUT, HDBT OUT)
- Input (only encrypt the output when the active input is encrypted)
and 4 more, all in the setup guide
The units
Only what differs per unit. Each unit's build sheet has every setting worked out.Nothing is ready for you here. Keia Atlas keeps checking these units.
| Unit | Provision | Install | Configure | |
|---|---|---|---|---|
| Build sheet | ||||
| Build sheet | ||||
Setup order
Optional: tick as you go, or let the checks do it1Rack-mount VP-440H2 and connect the HDMI/HDBT/VGA/mic inputs and the HDMI and HDBT outputs.0/2
2Connect Ethernet and, from the front-panel OSD or web pages, set the network mode below.0/2
3Browse to the web pages and turn on password protection; it ships unsecured.0/2
4Set HDCP per input/output and manage EDID so every input matches the space's display.0/2
5Set Auto Switching and Auto-Sync Off to match how the space's sources are used.0/2
6Set the OSD and audio/mic defaults for the space.0/2
7Firmware is applied by uploading a file on the Device Settings web page; there is no automatic-update option to turn off.0/2
Every setting
12 in the setup guide, as patternsValues marked Per unit are patterns here. Each unit's build sheet has them worked out: 4.03 Heron, 4.05 Gannet.
Network2
- IP MODEAdvanced > ETHERNET > IP MODESet to DHCP, with a reservation on the AV VLAN
Why
Aigna's AV devices sit on a DHCP-reserved address on the AV VLAN rather than a hand-typed static one.
- CONTROL PORTAdvanced > ETHERNET > CONTROL PORTCheck it is Kramer's default IP control port
Why
Left at the vendor default unless a site's controller needs a different port.
Security2
- Authenticate Web Pages accessAuthenticationSet to On
Why
The web pages are not secured out of the box; Aigna turns this on before the unit goes into service.
- Web pages user name and passwordPer unitAuthenticationSet to From the password vault, per siteWorked out on each build sheet
Why
Set alongside turning authentication on, so the unit is never left with a blank or shared login.
HDCP2
- HDCP on inputs (HDBT, HDMI1-3)Advanced > HDCP ON INPUTSet to ON for every input
Why
Lets any HDCP-protected laptop or source play through without per-space tweaking.
- HDCP on outputs (HDMI OUT, HDBT OUT)Advanced > HDCP ON OUTPUTSet to Input (only encrypt the output when the active input is encrypted)
Why
Keeps an unprotected source compatible with a display or extender that doesn't support HDCP.
EDID1
- EDID source for each inputPer unitAdvanced > EDID MANAGESet to Copy the connected display's own EDID to every inputWorked out on each build sheet
Why
Matches every input's reported resolution and audio format to what the space's actual display supports, rather than a generic default EDID.
Switching2
- AUTO-SYNC OFFAdvanced > AUTO-SYNC OFFSet to SLOW (about 2 minutes)
Why
Lets the unit shut down after a meeting ends without cutting out during a brief signal gap.
- AUTO SWITCHINGAdvanced > AUTO SWITCHINGSet to Last connected
Why
Aigna's rooms are BYOM-first; whichever source was just plugged in should take over automatically.
OSD and audio2
- OSD DISPLAYOSD > DISPLAYSet to INFO (shown for 10 seconds)
Why
Gives the space a brief on-screen confirmation of the active source without leaving a permanent overlay.
- MIC MODEAudio > MIC SETTINGS > MIC MODESet to OFF
Why
Aigna's Google Meet rooms take audio from the Poly Studio X bar, not this scaler's mic input; left off unless a space specifically wires a mic here.
Firmware1
- Firmware update methodCheck it is Manual upload only, no automatic-update toggle exists
Why
There's nothing to turn off; firmware only changes when an installer manually uploads a file, which already matches Aigna's Lab-first policy.