Vendor access
This part is for Aigna staff
Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.
Go to your installationModule
Projects is switched off
Projects, the schedule, planning, the work plan and the Lab. This demo has the Projects module switched off in Organisation settings.
Build sheetBatch 11 of 12Project PRJ-19Simulated live
mel-801-sig01
2 values not recorded yet · 11 settings to set, 12 to checkchecked just now
Asset register
Assetbox › Assets- Asset tagAssetbox › Assets
The install recordAG-000492CheckThis unitNot seen yet - Serial numberAssetbox › Assets
The install recordDEMO-MEL-000492CheckThis unitNot seen yet - ModelAssetbox › Assets
The space typeBrightSign XT1145CheckEvery unitNot seen yet - LocationAssetbox › Assets
The spaceMelbourne office, 8.01 ReceptionSetThis unitNot seen yet
DHCP and DNS
InfoDNS › Records- DNS name (A and PTR records)InfoDNS › DNS
The hostname and the house domainmel-801-sig01.aigna.exampleSetThis unitNot seen yet - DHCP reservationInfoDNS › DHCP › Reservations
The site's address plan (simulated)10.70.8.165SetThis unitNot seen yet - MAC address for the reservationInfoDNS › DHCP › Reservations
Not recordedNot recorded yet. The installer reads it from the unit's label and records it with the serial.
SetThis unitNot seen yet - DNS servers handed outInfoDNS › DHCP › Scope options
The Asia Pacific resolvers10.60.0.53, 10.60.0.54CheckEvery unitNot seen yet - Time servers handed out (option 42)InfoDNS › DHCP › Scope options
The house time serversntp1.aigna.example, ntp2.aigna.exampleCheckEvery unitNot seen yet
Switch port
Network controller › Ports- VLAN (native, untagged)Network controller › Ports
The network standard: VLAN by purpose31 Displays and signageSetEvery unitNot seen yet - PortNetwork controller › Ports
The port it is patched to (simulated)mel-801-sw01 port 8CheckThis unitNot seen yet
Firmware
Local DWS- Firmware versionLocal DWS
Not recordedNo fleet standard firmware for this model yet. The configuration was checked on 9.1.151.
CheckEvery unitNot checked
Network (BrightAuthor:Connected)
BrightAuthor:Connected › Network tabLocal DWS (on-site diagnostics)
Device web interface (Local DWS)- Enable Local Diagnostic Web ServerDevice web interface (Local DWS) › BrightAuthor:Connected › player settings › Enable Local Diagnostic Web Server
The setup guide, the same on every unitOnSetEvery unitNot read back yet - Set PasswordDevice web interface (Local DWS) › Local DWS › Control tab › Set Password
From the password vault,
The password vault. The secret itself is never shown here.Melbourne office / AV / BrightSign XT1145 / Set PasswordSetThis unitNot read back yet
Updates
Local DWS- BrightSignOS UpdateLocal DWS › Advanced tab › BrightSignOS Update (production/beta/custom)
The setup guide, the same on every unitProduction, applied manually after the Lab passes itSetEvery unitNot read back yet
BSN.cloud registration
BSN.cloud- Device NameBSN.cloud
The unit's hostname, from its install recordmel-801-sig01SetThis unitNot read back yet - Setup file network configurationBSN.cloud
The setup guide, the same on every unitUse current device settingsCheckEvery unitNot read back yet
BrightSign BSN.cloud
BrightSign BSN.cloud › Group- OrganisationBrightSign BSN.cloud › Organisation
The house valuesAigna signageCheckEvery unitNot read back yet - GroupBrightSign BSN.cloud › Group
The house values, for Melbourne officeMelbourne officeSetEvery unitNot read back yet
No setting matches these filters.