Keia Atlas

Vendor access

This part is for Aigna staff

Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.

Go to your installation

Module

Locations is switched off

Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.

Organisation settings

SpaceCHIChicago office · Level 13In service

13.14 Office 13.14

All 1 unit in service · no open incidentschecked just now

Lockable credenzaPlate B: Wall plate outside the door, behind the booking panel. 1 data port. Data 1: scheduler panel (optional)Coat hookOpen credenza, 36 inOpen credenza, 36 inMarker boardPlate A: Wall plate on the wall below the table. 4 Type B sockets, 2 data ports. Power 1: 34 inch monitor Power 2: spare Power 3: spare Power 4: spare Data 1: 34 inch monitor Data 2: sparePlate A: Wall plate on the wall below the table. 4 Type B sockets, 2 data ports. Power 1: 34 inch monitor Power 2: spare Power 3: spare Power 4: spare Data 1: 34 inch monitor Data 2: spare1. 34 inch monitor, Dell Pro P 34 USB-C Hub Conferencing Monitor (P3426WEB) · On the desk1. 34 inch monitor, Dell Pro P 34 USB-C Hub Conferencing Monitor (P3426WEB) · On the desk1. 34 inch monitor, Dell Pro P 34 USB-C Hub Conferencing Monitor (P3426WEB) · On the desk1. 34 inch monitor, Dell Pro P 34 USB-C Hub Conferencing Monitor (P3426WEB) · On the deskLaptopLaptopTray under the deskDown the desk legFloor cable coverSkirting trunkingSkirting trunkingPlate A: cabled up inside the wall to the ceiling above the door, back to the comms roomUSB-C: 34 inch monitor USB-C 1 to a laptop, via the desk trayCat 6: 34 inch monitor LAN to plate A, data 1, via the desk tray, the desk leg, the floor cable cover and the skirting trunkingPower: 34 inch monitor power to plate A, power 1, via the desk tray, the desk leg, the floor cable cover and the skirting trunkingWhere the data comes in: above the door, from Comms room (IDF) 13.201. 34 inch monitor1Plate A: Wall plate on the wall below the table. 4 Type B sockets, 2 data ports. Power 1: 34 inch monitor Power 2: spare Power 3: spare Power 4: spare Data 1: 34 inch monitor Data 2: spareAPlate B: Wall plate outside the door, behind the booking panel. 1 data port. Data 1: scheduler panel (optional)B

Drawn to scale · 3.66 × 3.05 m, 11.14 m² · 3 seats · Outlets: Type A, B sockets; US plates, 70 mm wide and 46 mm more a gang, 450 mm up to the centre (house default; the space type gives no height) · Desk 72 × 30 in, two 36 in open credenzas and a lockable one

Incidents

No incidents recorded for this space.

All incidents at Chicago office

Compared against

Private office

Standard: A 34 inch monitor with camera and dock, optionally a second 27 inch.

Required devices
All recorded
Optional fitted
None of 2
Wiring
Checks pass
Laptops
macOS, Windows

Lifecycle

In service
1

Accessibility

Live captions and step-free access

Hearing loop
None in this room
Live captions
On in calls, from the touch panel
Step-free access
Yes
Last walked through
20 Apr 2026, by facilities, Chicago office, with the local AV technician

From the office's accessibility record (demo), the same one the room guide reads to people in the room.

Cable tests

Restricted: rack and switch ports

All 3 links passed certification · closest margin 3.0 dB · last tested 24 Mar 2020

LinkOutletCableLengthResultMarginTested
CHI-13.20-R1-U34-P05Wall, below the table, 1Cat6A34.33 mPass2.98 dB24 Mar 2020
CHI-13.20-R1-U34-P06Wall, below the table, 2Cat6A34.56 mPass4.86 dB24 Mar 2020
CHI-13.20-R1-U34-P07At the door, 1Cat6A28.94 mPass4.14 dB24 Mar 2020

From the cabling contractor's certification report, recorded on each run (made up for the demo). A margin under 3 dB passes but is worth a look.

Room guide and QR

What people in the space see

The code on the table opens this space's guide: how to start a meeting and share a screen, and a two-tap way to report a problem or ask for something.

Sent from the guide

    Nothing sent from this space's guide yet. Reports appear here, on the Incidents board and on Home as they arrive.

    Outlets

    For this space
    ServiceWhereHow manyServesProvided by
    PowerWall, below the table4monitor, spare, spare, spareFacilities
    DataWall, below the table2monitor, spareOnly one is patched to a switch port.IT
    DataAt the door1scheduler panel (optional)IT

    Wiring

    1 signal cable, 2 to outlets
    USB
    Where it startsWhere it endsUSB-C: 34 inch monitor, usb-c-1 to Laptop34 inch monitor, Dell Pro P 34 USB-C Hub Conferencing Monitor (P3426WEB)34 inch monitorDell Pro P 34 USB-C Hub Confere…usb-c-1 · USB-CNetwork, wall, below the desk #1Network, wall, below the desk …Power, wall, below the desk #1Power, wall, below the desk #1Laptop, The person's ownLaptopThe person's owncable
    List every cable
    CableFromTo
    USB-C34 inch monitor, usb-c-1LaptopOne cable: picture, network and charging
    Cat 634 inch monitor, lan-1Data outlet 1, wall, below the table
    Power34 inch monitor, power-inPower outlet 1, wall, below the table

    View as

    See Keia Atlas the way someone else does. A demo: nobody signs in.

    Viewing asAnna ByrneAV and IT delivery engineer · EMEA

    Suggested

    Delivery

    • Delivery engineerDesigns and commissions spaces, from survey to handover
    • Project managerRuns projects day to day: dates, suppliers and who does what
    • On-site technicianInstalls and fixes kit in the offices
    • Programme managerPlans the year of projects across every region
    • Engineering managerLeads the delivery engineers
    • Project management leadLeads the project managers
    • On-site services managerLeads the on-site technicians
    • Delivery managerThe whole delivery team, every region

    Support and service

    • Service desk analystTakes incidents as they arrive and routes them
    • Network engineerPorts, VLANs and patching
    • Service manager, AVOwns the AV standard and its service
    • Service manager, networkOwns the network standard and its service

    The Lab

    • Innovation engineerTests new kit before it ships

    Leadership

    • Head of AV and ITThe whole service, every region

    Partners

    • Integration vendorSees their own installations only
    • Service vendorRepairs under the service contract

    Overview

    • EveryoneEvery role's first screen at once, to see the whole picture

    Settings

    Appearance
    LookStudio
    Text size
    Default

    Report

    Tell the team

    About 13.14 Office 13.14, Chicago office

    Goes to Sofia Reyes, Service manager, AV. Reviewed within five working days.