Keia Atlas

Vendor access

This part is for Aigna staff

Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.

Go to your installation

Module

Projects is switched off

Projects, the schedule, planning, the work plan and the Lab. This demo has the Projects module switched off in Organisation settings.

Organisation settings

Build sheetBatch 1 of 16Project PRJ-22Simulated live

dub-303-sw01

3 values not recorded yet · 11 settings to set, 9 to checkchecked just now

Filters

Asset register

Assetbox › Assets
  1. Asset tagAssetbox › Assets

    AG-000291

    The install record
    CheckThis unit
    Not seen yet
  2. Serial numberAssetbox › Assets

    DEMO-DUB-000291

    The install record
    CheckThis unit
    Not seen yet
  3. ModelAssetbox › Assets

    Netgear AV Line M4250-9G1F-PoE+ (GSM4210PD)

    The space type
    CheckEvery unit
    Not seen yet
  4. LocationAssetbox › Assets

    Dublin office, 3.03 Heron

    The space
    SetThis unit
    Not seen yet

DHCP and DNS

InfoDNS › Records
  1. DNS name (A and PTR records)InfoDNS › DNS

    dub-303-sw01.aigna.example

    The hostname and the house domain
    SetThis unit
    Not seen yet
  2. DHCP reservationInfoDNS › DHCP › Reservations

    10.20.3.85

    The site's address plan (simulated)
    SetThis unit
    Not seen yet
  3. MAC address for the reservationInfoDNS › DHCP › Reservations

    Not recordedNot recorded yet. The installer reads it from the unit's label and records it with the serial.

    SetThis unit
    Not seen yet
  4. DNS servers handed outInfoDNS › DHCP › Scope options

    10.20.0.53, 10.20.0.54

    The Europe, Middle East and Africa resolvers
    CheckEvery unit
    Not seen yet
  5. Time servers handed out (option 42)InfoDNS › DHCP › Scope options

    ntp1.aigna.example, ntp2.aigna.example

    The house time servers
    CheckEvery unit
    Not seen yet

Switch port

Network controller › Ports
  1. VLAN (native, untagged)Network controller › Ports

    10 Management

    The network standard: VLAN by purpose
    SetEvery unit
    Not seen yet
  2. PortNetwork controller › Ports

    dub-303-sw01 port 3

    The port it is patched to (simulated)
    CheckThis unit
    Not seen yet

Firmware

Device web interface
  1. Firmware versionDevice web interface

    Not recordedNo fleet standard firmware for this model yet. The configuration was checked on 13.0.5.26.

    CheckEvery unit
    Not checked

Network Profiles (AV UI)

Device web interface
  1. Network ProfileDevice web interface › Configure › Network Profiles

    Not recordedDecided or measured on site, during setup or commissioning, so it is not recorded before. Note it on the unit afterwards.

    SetThis unit
    Confirm by hand
  2. Port assignment (untagged/tagged/excluded)Device web interface › Configure › Network Profiles › [Network Profile] › ports

    AV endpoints untagged on the Network Profile's VLAN; the uplink tagged

    The setup guide: the same instruction on every unit
    SetEvery unit
    Confirm by hand
  3. Querier Election ParticipateDevice web interface › Configure › Network Profiles › [Network Profile] › Querier

    On

    The setup guide, the same on every unit
    CheckEvery unit
    Confirm by hand

Management access

Device web interface
  1. Admin passwordDevice web interface

    From the password vault, Dublin office / AV / Netgear AV Line M4250-9G1F-PoE+ (GSM4210PD) / Admin password

    The password vault. The secret itself is never shown here.
    SetThis unit
    Confirm by hand
  2. Management access protocolDevice web interface

    HTTPS

    The setup guide, the same on every unit
    CheckEvery unit
    Confirm by hand

Date and time

Device web interface
  1. SNTP serverDevice web interface › Configure › Date and time settings

    ntp1.aigna.example

    The house time servers
    SetEvery unit
    Confirm by hand

Power over Ethernet

Device web interface
  1. PoE port power allocationDevice web interface › Configure › Power over Ethernet

    Per the connected device's power class, within the 110 W total budget

    The setup guide: the same instruction on every unit
    SetEvery unit
    Confirm by hand

Updates

Device web interface
  1. Firmware updateDevice web interface › Manage and Monitor

    Manual, downloaded from netgear.com/support/download and applied after the Lab passes it

    The setup guide, the same on every unit
    SetEvery unit
    Confirm by hand

View as

See Keia Atlas the way someone else does. A demo: nobody signs in.

Viewing asAnna ByrneAV and IT delivery engineer · EMEA

Suggested

Delivery

  • Delivery engineerDesigns and commissions spaces, from survey to handover
  • Project managerRuns projects day to day: dates, suppliers and who does what
  • On-site technicianInstalls and fixes kit in the offices
  • Programme managerPlans the year of projects across every region
  • Engineering managerLeads the delivery engineers
  • Project management leadLeads the project managers
  • On-site services managerLeads the on-site technicians
  • Delivery managerThe whole delivery team, every region

Support and service

  • Service desk analystTakes incidents as they arrive and routes them
  • Network engineerPorts, VLANs and patching
  • Service manager, AVOwns the AV standard and its service
  • Service manager, networkOwns the network standard and its service

The Lab

  • Innovation engineerTests new kit before it ships

Leadership

  • Head of AV and ITThe whole service, every region

Partners

  • Integration vendorSees their own installations only
  • Service vendorRepairs under the service contract

Overview

  • EveryoneEvery role's first screen at once, to see the whole picture

Settings

Appearance
LookStudio
Text size
Default

Report

Tell the team

About Heron in-room network switch, build sheet (PRJ-22)

Goes to Sofia Reyes, Service manager, AV. Reviewed within five working days.