Keia Atlas

Vendor access

This part is for Aigna staff

Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.

Go to your installation

Module

Locations is switched off

Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.

Organisation settings

SupportHouse standard

Control room (backstage AV)

1 space built to it · no open incidents

Plate C: Wall plate on the wall. 8 plain sockets, 4 data ports. Power 1: charging cabinet Power 2: charging cabinet Power 3: charging cabinet Power 4: charging cabinet Power 5: spare Power 6: spare Power 7: spare Power 8: spare Data 1: demo kit staging Data 2: demo kit staging Data 3: spare Data 4: sparePlate C: Wall plate on the wall. 8 plain sockets, 4 data ports. Power 1: charging cabinet Power 2: charging cabinet Power 3: charging cabinet Power 4: charging cabinet Power 5: spare Power 6: spare Power 7: spare Power 8: spare Data 1: demo kit staging Data 2: demo kit staging Data 3: spare Data 4: sparePlate C: Wall plate on the wall. 8 plain sockets, 4 data ports. Power 1: charging cabinet Power 2: charging cabinet Power 3: charging cabinet Power 4: charging cabinet Power 5: spare Power 6: spare Power 7: spare Power 8: spare Data 1: demo kit staging Data 2: demo kit staging Data 3: spare Data 4: sparePlate B: Wall plate on the wall below the table. 2 plain sockets, 2 data ports. Power 1: touch controller Power 2: spare Data 1: The operator's controller, paired with the auditorium's codec over the network Data 2: sparePlate B: Wall plate on the wall below the table. 2 plain sockets, 2 data ports. Power 1: touch controller Power 2: spare Data 1: The operator's controller, paired with the auditorium's codec over the network Data 2: sparePlate A: Wall plate behind the display. 2 plain sockets, 2 data ports. Power 1: Monitoring display for the auditorium's programme and far end Power 2: spare Data 1: Monitoring display for the auditorium's programme and far end Data 2: sparePlate A: Wall plate behind the display. 2 plain sockets, 2 data ports. Power 1: Monitoring display for the auditorium's programme and far end Power 2: spare Data 1: Monitoring display for the auditorium's programme and far end Data 2: spare1. Monitoring display for the auditorium's programme and far end, Samsung QM65C (65 in shown) · Display wall2. The operator's controller, paired with the auditorium's codec over the network, Poly TC10 · On the deskCharging cabinet for the demo kitAV rack: the auditorium codec, amplifier and switchesTrack behind the displayTray under the deskDown the desk legFloor cable coverSkirting trunkingSkirting trunkingPlate A: cabled up inside the wall to the ceiling above the door, back to the comms roomPlate B: cabled up inside the wall to the ceiling above the door, back to the comms roomPlate C: cabled up inside the wall to the ceiling above the door, back to the comms roomCat 6: Monitoring display for the auditorium's programme and far end LAN to plate A, data 1, via the track behind the displayPower: Monitoring display for the auditorium's programme and far end power to plate A, power 1, via the track behind the displayCat 6: The operator's controller LAN to plate B, data 1, via the desk tray, the desk leg, the floor cable cover and the skirting trunkingWhere the data comes in: above the door, from the floor's comms room1. Monitoring display for the auditorium's programme and far end12. The operator's controller, paired with the auditorium's codec over the network2Plate C: Wall plate on the wall. 8 plain sockets, 4 data ports. Power 1: charging cabinet Power 2: charging cabinet Power 3: charging cabinet Power 4: charging cabinet Power 5: spare Power 6: spare Power 7: spare Power 8: spare Data 1: demo kit staging Data 2: demo kit staging Data 3: spare Data 4: spareCPlate B: Wall plate on the wall below the table. 2 plain sockets, 2 data ports. Power 1: touch controller Power 2: spare Data 1: The operator's controller, paired with the auditorium's codec over the network Data 2: spareBPlate A: Wall plate behind the display. 2 plain sockets, 2 data ports. Power 1: Monitoring display for the auditorium's programme and far end Power 2: spare Data 1: Monitoring display for the auditorium's programme and far end Data 2: spareA

Drawn to scale · 6.40 × 5.00 m, 32 m² · 2 seats · Outlets: plain outlets (a space type has no country), 450 mm up to the centre (house default; the space type gives no height) · Operator desk for two facing the monitoring display, the AV rack and a charging cabinet (house choice)

Outlets

2Power, behind the displaymonitoring display, spareIT
2Data, behind the displaymonitoring display, spareIT
2Data, wall, below the tabletouch controller, spareIT
2Power, wall, below the tabletouch controller, spareIT
4Data, walldemo kit staging, demo kit staging, spare, spareAt the charging cabinet, for setting up and updating demo kit before a briefingIT
8Power, wallcharging cabinet, charging cabinet, charging cabinet, charging cabinet, spare, spare, spare, spareIT

Wiring

0 signal cables, 3 to outlets
DevicesMonitoring display for the auditorium's programme and far end, Samsung QM65CMonitoring display forthe auditorium's…Samsung QM65CNetwork, behind the display #1Network, behind the display #1Power, behind the display #1Power, behind the display #1The operator's controller, paired with the auditorium's codec over the network, Poly TC10The operator'scontroller, paired…Poly TC10Network, wall, below the desk #1Network, wall, below the desk …
List every cable
CableFromTo
Cat 6Monitoring display for the auditorium's programme and far end, lan-1Data outlet 1, behind the display
PowerMonitoring display for the auditorium's programme and far end, power-inPower outlet 1, behind the display
Cat 6The operator's controller, paired with the auditorium's codec over the network, lan-1Data outlet 1, wall, below the tablePoE powers the controller

Spaces built to it

1 space

View as

See Keia Atlas the way someone else does. A demo: nobody signs in.

Viewing asAnna ByrneAV and IT delivery engineer · EMEA

Suggested

Delivery

  • Delivery engineerDesigns and commissions spaces, from survey to handover
  • Project managerRuns projects day to day: dates, suppliers and who does what
  • On-site technicianInstalls and fixes kit in the offices
  • Programme managerPlans the year of projects across every region
  • Engineering managerLeads the delivery engineers
  • Project management leadLeads the project managers
  • On-site services managerLeads the on-site technicians
  • Delivery managerThe whole delivery team, every region

Support and service

  • Service desk analystTakes incidents as they arrive and routes them
  • Network engineerPorts, VLANs and patching
  • Service manager, AVOwns the AV standard and its service
  • Service manager, networkOwns the network standard and its service

The Lab

  • Innovation engineerTests new kit before it ships

Leadership

  • Head of AV and ITThe whole service, every region

Partners

  • Integration vendorSees their own installations only
  • Service vendorRepairs under the service contract

Overview

  • EveryoneEvery role's first screen at once, to see the whole picture

Settings

Appearance
LookStudio
Text size
Default

Report

Tell the team

About Control room (backstage AV)

Goes to Sofia Reyes, Service manager, AV. Reviewed within five working days.