Out of service
Who was told Simulated from the booking system
Notes from the team
Drawn to scale · 6.40 × 5.00 m, 32 m² · 2 seats · Outlets: Type G sockets; UK and Ireland plates, 86 and 146 mm wide, 450 mm up to the centre (house default; the space type gives no height) · Operator desk for two facing the monitoring display, the AV rack and a charging cabinet (house choice)
Compared against
Operator desk and AV rack: A 65 in monitoring display and a Poly TC10 for the operator, data and power for the AV rack, and a charging cabinet for the demo kit with its own outlets. The auditorium's codec, amplifier, AV switch and display transmitters stand in the AV rack here but are recorded with the auditorium. Lighting scenes for the auditorium are run from here through the building's lighting control; recording and streaming take the codec's feed here.
- Required devices
- All recorded
- Wiring
- Checks pass
Lifecycle
- In service
- 2
Meeting platforms
The the operator's controller, paired with the auditorium's codec over the network is certified for Google Meet and Microsoft Teams Rooms
- Poly TC10The operator's controller, paired with the auditorium's codec over the networkGoogle MeetMicrosoft Teams Rooms
Accessibility
Live captions and step-free access
- Hearing loop
- None in this room
- Live captions
- On in calls, from the touch panel
- Step-free access
- Yes
- Last walked through
- 9 Jul 2026, by facilities, Dublin office, with the local AV technician
From the office's accessibility record (demo), the same one the room guide reads to people in the room.
Cable tests
Restricted: rack and switch portsAll 8 links passed certification · closest margin 3.5 dB · last tested 26 Jun 2026
| Link | Outlet | Cable | Length | Result | Margin | Tested |
|---|---|---|---|---|---|---|
| DUB-5.21-R1-U34-P02 | Behind the display, 1 | Cat6A | 54.92 m | Pass | 6.20 dB | 26 Jun 2026 |
| DUB-5.21-R1-U34-P03 | Behind the display, 2 | Cat6A | 54.74 m | Pass | 6.42 dB | 26 Jun 2026 |
| DUB-5.21-R1-U34-P04 | Wall, below the table, 1 | Cat6A | 54.2 m | Pass | 5.60 dB | 26 Jun 2026 |
| DUB-5.21-R1-U34-P05 | Wall, below the table, 2 | Cat6A | 54.03 m | Pass | 3.98 dB | 26 Jun 2026 |
| DUB-5.21-R1-U34-P06 | Wall, 1 | Cat6A | 53.14 m | Pass | 5.08 dB | 26 Jun 2026 |
| DUB-5.21-R1-U34-P07 | Wall, 2 | Cat6A | 53.1 m | Pass | 3.72 dB | 26 Jun 2026 |
| DUB-5.21-R1-U34-P08 | Wall, 3 | Cat6A | 53.11 m | Pass | 3.53 dB | 26 Jun 2026 |
| DUB-5.21-R1-U34-P09 | Wall, 4 | Cat6A | 53.28 m | Pass | 4.78 dB | 26 Jun 2026 |
From the cabling contractor's certification report, recorded on each run (made up for the demo). A margin under 3 dB passes but is worth a look.
Room guide and QR
What people in the space seeThe code on the table opens this space's guide: how to start a meeting and share a screen, and a two-tap way to report a problem or ask for something.
Sent from the guide
Nothing sent from this space's guide yet. Reports appear here, on the Incidents board and on Home as they arrive.
Outlets
For this space| Service | Where | How many | Serves | Provided by |
|---|---|---|---|---|
| Power | Behind the display | 2 | monitoring display, spare | IT |
| Data | Behind the display | 2 | monitoring display, spare | IT |
| Data | Wall, below the table | 2 | touch controller, spare | IT |
| Power | Wall, below the table | 2 | touch controller, spare | IT |
| Data | Wall | 4 | demo kit staging, demo kit staging, spare, spareAt the charging cabinet, for setting up and updating demo kit before a briefing | IT |
| Power | Wall | 8 | charging cabinet, charging cabinet, charging cabinet, charging cabinet, spare, spare, spare, spare | IT |
Wiring
0 signal cables, 3 to outletsList every cable
| Cable | From | To |
|---|---|---|
| Cat 6 | Monitoring display for the auditorium's programme and far end, lan-1 | Data outlet 1, behind the display |
| Power | Monitoring display for the auditorium's programme and far end, power-in | Power outlet 1, behind the display |
| Cat 6 | The operator's controller, paired with the auditorium's codec over the network, lan-1 | Data outlet 1, wall, below the tablePoE powers the controller |