Notes from the team
What's installed
8 devicesEach desk has
| Desk | Monitor | Stage |
|---|---|---|
| Desk 01 | DEMO-CHI-000147AG-000147 | In service |
| Desk 02 | DEMO-CHI-000148AG-000148 | In service |
| Desk 03 | DEMO-CHI-000149AG-000149 | In service |
| Desk 04 | DEMO-CHI-000150AG-000150 | In service |
| Desk 05 | DEMO-CHI-000151AG-000151 | In service |
| Desk 06 | DEMO-CHI-000152AG-000152 | In service |
| Desk 07 | DEMO-CHI-000153AG-000153 | In service |
| Desk 08 | DEMO-CHI-000154AG-000154 | In service |
Compared against
Ultrawide 34 inch: A 34 inch monitor with a built-in dock: video, network and 90 W charging.
- Required devices
- All recorded
- Wiring
- Checks pass
- Laptops
- macOS, Windows
Lifecycle
- In service
- 8
Cable tests
Restricted: rack and switch portsAll 16 links passed certification · closest margin 2.7 dB · last tested 24 Mar 2020
| Link | Outlet | Cable | Length | Result | Margin | Tested |
|---|---|---|---|---|---|---|
| CHI-13.20-R1-U30-P31 | Desk 01/data/table top#1 | Cat6A | 34.77 m | Pass | 5.27 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P32 | Desk 01/data/table top#2 | Cat6A | 34.87 m | Pass | 2.86 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P33 | Desk 02/data/table top#1 | Cat6A | 36.53 m | Pass | 3.81 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P34 | Desk 02/data/table top#2 | Cat6A | 36.26 m | Pass | 4.91 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P35 | Desk 03/data/table top#1 | Cat6A | 34.81 m | Pass | 4.83 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P36 | Desk 03/data/table top#2 | Cat6A | 35.02 m | Pass | 5.86 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P37 | Desk 04/data/table top#1 | Cat6A | 36.25 m | Pass | 2.73 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P38 | Desk 04/data/table top#2 | Cat6A | 36.51 m | Pass | 3.44 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P39 | Desk 05/data/table top#1 | Cat6A | 37.98 m | Pass | 4.79 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P40 | Desk 05/data/table top#2 | Cat6A | 38.21 m | Pass | 4.26 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P41 | Desk 06/data/table top#1 | Cat6A | 39.42 m | Pass | 4.73 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P42 | Desk 06/data/table top#2 | Cat6A | 39.68 m | Pass | 6.37 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P43 | Desk 07/data/table top#1 | Cat6A | 38.3 m | Pass | 4.59 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P44 | Desk 07/data/table top#2 | Cat6A | 38.16 m | Pass | 2.87 dB | 24 Mar 2020 |
| CHI-13.20-R1-U30-P45 | Desk 08/data/table top#1 | Cat6A | 39.53 m | Pass | 5.63 dB | 24 Mar 2020 |
| CHI-13.20-R1-U26-P01 | Desk 08/data/table top#2 | Cat6A | 39.76 m | Pass | 5.84 dB | 24 Mar 2020 |
From the cabling contractor's certification report, recorded on each run (made up for the demo). A margin under 3 dB passes but is worth a look.
Outlets
Per desk| Service | Where | How many | Serves | Provided by |
|---|---|---|---|---|
| Power | On the desk | 4 | monitor or dock, spare, spare, spare | IT |
| Data | On the desk | 2 | monitor or dock, spareOnly one is patched to a switch port. | IT |
Wiring
1 signal cable, 2 to outletsThe same at every desk.
List every cable
| Cable | From | To |
|---|---|---|
| Thunderbolt | Monitor, usb-c-2 | LaptopOne cable: picture, network and charging |
| Cat 6 | Monitor, lan-1 | Data outlet 1, on the desk |
| Power | Monitor, power-in | Power outlet 1, on the desk |