Vendor access
This part is for Aigna staff
Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.
Go to your installationModule
Locations is switched off
Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.
- 1Person
- 3.34m²
- 4Build options
- 17Spaces built to it
Drawn to scale · 3.34 m² per workstation (the drawing shows 4.1 × 5.6 m of floor) · 1 seat · Outlets: a desk module, 52 mm a socket (house default) · Desk 60 × 30 in in runs of 4 to 8, 84 in (2.1 m) back to back; the coloured desk is one workstation
Outlets
Power for the space's kit is never on a light switch, so nothing turns it off (house assumption).
Wiring
1 signal cable, 2 to outletsList every cable
| Cable | From | To |
|---|---|---|
| Thunderbolt | Monitor, usb-c-2 | LaptopOne cable: picture, network and charging |
| Cat 6 | Monitor, lan-1 | Data outlet 1, on the desk |
| Power | Monitor, power-in | Power outlet 1, on the desk |
Spaces built to it
7 spacesDrawn to scale · 3.34 m² per workstation (the drawing shows 4.1 × 5.6 m of floor) · 1 seat · Outlets: a desk module, 52 mm a socket (house default) · Desk 60 × 30 in in runs of 4 to 8, 84 in (2.1 m) back to back; the coloured desk is one workstation
Outlets
Power for the space's kit is never on a light switch, so nothing turns it off (house assumption).
Wiring
1 signal cable, 2 to outletsList every cable
| Cable | From | To |
|---|---|---|
| Thunderbolt | Monitor, usb-c-2 | LaptopOne cable: picture, network and charging |
| Cat 6 | Monitor, lan-1 | Data outlet 1, on the desk |
| Power | Monitor, power-in | Power outlet 1, on the desk |
Spaces built to it
2 spacesDrawn to scale · 3.34 m² per workstation (the drawing shows 4.1 × 5.6 m of floor) · 1 seat · Outlets: a desk module, 52 mm a socket (house default) · Desk 60 × 30 in in runs of 4 to 8, 84 in (2.1 m) back to back; the coloured desk is one workstation
Outlets
Power for the space's kit is never on a light switch, so nothing turns it off (house assumption).
Wiring
2 signal cables, 3 to outletsList every cable
| Cable | From | To |
|---|---|---|
| Thunderbolt | Hub monitor, usb-c-2 | LaptopThunderbolt 4, 40 Gb/s, for two monitors |
| DisplayPort | Hub monitor, displayport-out-1 | Second monitor, fed over DisplayPort from the hub monitor, displayport-in-1Daisy chain |
| Cat 6 | Hub monitor, lan-1 | Data outlet 1, on the desk |
| Power | Hub monitor, power-in | Power outlet 1, on the desk |
| Power | Second monitor, fed over DisplayPort from the hub monitor, power-in | Power outlet 2, on the desk |
Spaces built to it
2 spacesDrawn to scale · 3.34 m² per workstation (the drawing shows 4.1 × 5.6 m of floor) · 1 seat · Outlets: a desk module, 52 mm a socket (house default) · Desk 60 × 30 in in runs of 4 to 8, 84 in (2.1 m) back to back; the coloured desk is one workstation
Outlets
Power for the space's kit is never on a light switch, so nothing turns it off (house assumption).
Wiring
2 signal cables, 1 to outletsList every cable
| Cable | From | To |
|---|---|---|
| Thunderbolt | Monitor, usb-c-1 | LaptopThunderbolt 5: picture, camera and 96 W charging |
| USB-C | Wired network through one of the display's USB-C ports, usb-c-1 | Monitor, usb-c-3 |
| Cat 6 | Wired network through one of the display's USB-C ports, lan-1 | Data outlet 1, on the desk |