Keia Atlas

Vendor access

This part is for Aigna staff

Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.

Go to your installation

Module

Locations is switched off

Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.

Organisation settings

DesksDUBDublin office · Fourth floorIn service

4.20 Assigned desks D

No tracked devices · no open incidentschecked just now

What's installed

0 devices
Nothing here is tracked by unit. Personal setups: the monitor and dock are each person's own and are not tracked here.

Each desk has

DeskStage

Incidents

No incidents recorded for this space.

All incidents at Dublin office

Compared against

Assigned desk

Personal setup: Outlets only; the monitor and dock depend on the person's own setup.

Required devices
All recorded
Optional fitted
None of 1
Wiring
Checks pass

Lifecycle

Cable tests

Restricted: rack and switch ports

All 32 links passed certification · closest margin 2.6 dB · last tested 10 Oct 2026

LinkOutletCableLengthResultMarginTested
DUB-4.21-R1-U22-P08Desk 01/data/table top#1Cat6A47.03 mPass5.04 dB10 Oct 2026
DUB-4.21-R1-U22-P09Desk 01/data/table top#2Cat6A47.03 mPass3.15 dB10 Oct 2026
DUB-4.21-R1-U22-P10Desk 02/data/table top#1Cat6A48.38 mPass2.97 dB10 Oct 2026
DUB-4.21-R1-U22-P11Desk 02/data/table top#2Cat6A48.43 mPass5.04 dB10 Oct 2026
DUB-4.21-R1-U22-P12Desk 03/data/table top#1Cat6A50.15 mPass5.08 dB10 Oct 2026
DUB-4.21-R1-U22-P13Desk 03/data/table top#2Cat6A50.06 mPass3.89 dB10 Oct 2026
DUB-4.21-R1-U22-P14Desk 04/data/table top#1Cat6A51.56 mPass3.00 dB10 Oct 2026
DUB-4.21-R1-U22-P15Desk 04/data/table top#2Cat6A51.46 mPass2.71 dB10 Oct 2026
DUB-4.21-R1-U22-P16Desk 05/data/table top#1Cat6A46.99 mPass4.00 dB10 Oct 2026
DUB-4.21-R1-U22-P17Desk 05/data/table top#2Cat6A46.84 mPass5.04 dB10 Oct 2026
DUB-4.21-R1-U22-P18Desk 06/data/table top#1Cat6A48.46 mPass4.33 dB10 Oct 2026
DUB-4.21-R1-U22-P19Desk 06/data/table top#2Cat6A48.34 mPass5.86 dB10 Oct 2026
DUB-4.21-R1-U22-P20Desk 07/data/table top#1Cat6A49.91 mPass3.71 dB10 Oct 2026
DUB-4.21-R1-U22-P21Desk 07/data/table top#2Cat6A49.95 mPass3.31 dB10 Oct 2026
DUB-4.21-R1-U22-P22Desk 08/data/table top#1Cat6A51.57 mPass3.30 dB10 Oct 2026
DUB-4.21-R1-U22-P23Desk 08/data/table top#2Cat6A51.64 mPass4.81 dB10 Oct 2026
DUB-4.21-R1-U22-P24Desk 09/data/table top#1Cat6A41.1 mPass5.64 dB10 Oct 2026
DUB-4.21-R1-U22-P25Desk 09/data/table top#2Cat6A41 mPass5.97 dB10 Oct 2026
DUB-4.21-R1-U22-P26Desk 10/data/table top#1Cat6A42.57 mPass2.98 dB10 Oct 2026
DUB-4.21-R1-U22-P27Desk 10/data/table top#2Cat6A42.55 mPass5.45 dB10 Oct 2026
DUB-4.21-R1-U22-P28Desk 11/data/table top#1Cat6A44.16 mPass4.82 dB10 Oct 2026
DUB-4.21-R1-U22-P29Desk 11/data/table top#2Cat6A44.29 mPass3.66 dB10 Oct 2026
DUB-4.21-R1-U22-P30Desk 12/data/table top#1Cat6A45.8 mPass2.65 dB10 Oct 2026
DUB-4.21-R1-U22-P31Desk 12/data/table top#2Cat6A45.44 mPass3.73 dB10 Oct 2026
DUB-4.21-R1-U22-P32Desk 13/data/table top#1Cat6A41.14 mPass6.09 dB10 Oct 2026
DUB-4.21-R1-U22-P33Desk 13/data/table top#2Cat6A41.09 mPass4.69 dB10 Oct 2026
DUB-4.21-R1-U22-P34Desk 14/data/table top#1Cat6A42.4 mPass4.64 dB10 Oct 2026
DUB-4.21-R1-U22-P35Desk 14/data/table top#2Cat6A42.61 mPass3.24 dB10 Oct 2026
DUB-4.21-R1-U22-P36Desk 15/data/table top#1Cat6A44.12 mPass5.23 dB10 Oct 2026
DUB-4.21-R1-U22-P37Desk 15/data/table top#2Cat6A44.13 mPass6.30 dB10 Oct 2026
DUB-4.21-R1-U22-P38Desk 16/data/table top#1Cat6A45.52 mPass2.61 dB10 Oct 2026
DUB-4.21-R1-U22-P39Desk 16/data/table top#2Cat6A45.69 mPass4.56 dB10 Oct 2026

From the cabling contractor's certification report, recorded on each run (made up for the demo). A margin under 3 dB passes but is worth a look.

Outlets

Per desk
ServiceWhereHow manyServesProvided by
PowerOn the desk4monitors, laptop, dock and othersIT
DataOn the desk2monitor, laptop or dock, depending on the setupIT

Notes

  • Personal setups: the monitor and dock are each person's own and are not tracked here.

View as

See Keia Atlas the way someone else does. A demo: nobody signs in.

Viewing asAnna ByrneAV and IT delivery engineer · EMEA

Suggested

Delivery

  • Delivery engineerDesigns and commissions spaces, from survey to handover
  • Project managerRuns projects day to day: dates, suppliers and who does what
  • On-site technicianInstalls and fixes kit in the offices
  • Programme managerPlans the year of projects across every region
  • Engineering managerLeads the delivery engineers
  • Project management leadLeads the project managers
  • On-site services managerLeads the on-site technicians
  • Delivery managerThe whole delivery team, every region

Support and service

  • Service desk analystTakes incidents as they arrive and routes them
  • Network engineerPorts, VLANs and patching
  • Service manager, AVOwns the AV standard and its service
  • Service manager, networkOwns the network standard and its service

The Lab

  • Innovation engineerTests new kit before it ships

Leadership

  • Head of AV and ITThe whole service, every region

Partners

  • Integration vendorSees their own installations only
  • Service vendorRepairs under the service contract

Overview

  • EveryoneEvery role's first screen at once, to see the whole picture

Settings

Appearance
LookStudio
Text size
Default

Report

Tell the team

About 4.20 Assigned desks D, Dublin office

Goes to Sofia Reyes, Service manager, AV. Reviewed within five working days.