Keia Atlas

Vendor access

This part is for Aigna staff

Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.

Go to your installation

Module

Locations is switched off

Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.

Organisation settings

DesksJNUJuneau office · Second floorBeing installed

2.07 Flex desks A

Being installed · 8 units still going inchecked just now

What's installed

8 devices
DeskMonitorStage
Desk 01DEMO-JNU-000483AG-000483Being installed
Desk 02DEMO-JNU-000484AG-000484Being installed
Desk 03DEMO-JNU-000485AG-000485Being installed
Desk 04DEMO-JNU-000486AG-000486Being installed
Desk 05DEMO-JNU-000487AG-000487Being installed
Desk 06DEMO-JNU-000488AG-000488Being installed
Desk 07DEMO-JNU-000489AG-000489Being installed
Desk 08DEMO-JNU-000490AG-000490Being installed

Incidents

No incidents recorded for this space.

All incidents at Juneau office

Compared against

Hot desk

Single 27 inch: A 27 inch monitor with a built-in Thunderbolt 4 dock.

Required devices
All recorded
Wiring
Checks pass

Lifecycle

Being installed
8

Cable tests

Restricted: rack and switch ports

All 16 links passed certification · closest margin 2.5 dB · last tested 24 Aug 2026

LinkOutletCableLengthResultMarginTested
JNU-2.08-R1-U14-P13Desk 01/data/table top#1Cat6A27.91 mPass4.07 dB24 Aug 2026
JNU-2.08-R1-U14-P14Desk 02/data/table top#1Cat6A29.52 mPass4.99 dB24 Aug 2026
JNU-2.08-R1-U14-P15Desk 03/data/table top#1Cat6A28.26 mPass3.07 dB24 Aug 2026
JNU-2.08-R1-U14-P16Desk 04/data/table top#1Cat6A29.57 mPass3.75 dB24 Aug 2026
JNU-2.08-R1-U14-P17Desk 05/data/table top#1Cat6A25.03 mPass4.42 dB24 Aug 2026
JNU-2.08-R1-U14-P18Desk 06/data/table top#1Cat6A26.3 mPass4.38 dB24 Aug 2026
JNU-2.08-R1-U14-P19Desk 07/data/table top#1Cat6A24.87 mPass5.27 dB24 Aug 2026
JNU-2.08-R1-U14-P20Desk 08/data/table top#1Cat6A26.43 mPass5.82 dB24 Aug 2026
JNU-2.08-R1-U14-P33Desk 01/data/table top#2Cat6A28.1 mPass5.63 dB24 Aug 2026
JNU-2.08-R1-U14-P34Desk 02/data/table top#2Cat6A29.79 mPass5.48 dB24 Aug 2026
JNU-2.08-R1-U14-P35Desk 03/data/table top#2Cat6A27.95 mPass4.55 dB24 Aug 2026
JNU-2.08-R1-U14-P36Desk 04/data/table top#2Cat6A29.68 mPass2.53 dB24 Aug 2026
JNU-2.08-R1-U14-P37Desk 05/data/table top#2Cat6A25.06 mPass5.45 dB24 Aug 2026
JNU-2.08-R1-U14-P38Desk 06/data/table top#2Cat6A26.49 mPass6.14 dB24 Aug 2026
JNU-2.08-R1-U14-P39Desk 07/data/table top#2Cat6A25.09 mPass3.47 dB24 Aug 2026
JNU-2.08-R1-U14-P40Desk 08/data/table top#2Cat6A26.32 mPass4.61 dB24 Aug 2026

From the cabling contractor's certification report, recorded on each run (made up for the demo). A margin under 3 dB passes but is worth a look.

Outlets

Per desk
ServiceWhereHow manyServesProvided by
PowerOn the desk4monitor or dock, spare, spare, spareIT
DataOn the desk2monitor or dock, spareOnly one is patched to a switch port.IT

Wiring

1 signal cable, 2 to outlets
USB

The same at every desk.

Where it startsWhere it endsThunderbolt: Monitor, usb-c-2 to LaptopMonitor, Dell UltraSharp 27 Thunderbolt Hub Monitor (U2724DE)MonitorDell UltraSharp 27 Thunderbolt …usb-c-2 · USB-CNetwork, on the desk #1Network, on the desk #1Power, on the desk #1Power, on the desk #1Laptop, The person's ownLaptopThe person's owncable
List every cable
CableFromTo
ThunderboltMonitor, usb-c-2LaptopOne cable: picture, network and charging
Cat 6Monitor, lan-1Data outlet 1, on the desk
PowerMonitor, power-inPower outlet 1, on the desk

Notes

  • Juneau is being fitted out: devices are installed but not yet commissioned.

View as

See Keia Atlas the way someone else does. A demo: nobody signs in.

Viewing asAnna ByrneAV and IT delivery engineer · EMEA

Suggested

Delivery

  • Delivery engineerDesigns and commissions spaces, from survey to handover
  • Project managerRuns projects day to day: dates, suppliers and who does what
  • On-site technicianInstalls and fixes kit in the offices
  • Programme managerPlans the year of projects across every region
  • Engineering managerLeads the delivery engineers
  • Project management leadLeads the project managers
  • On-site services managerLeads the on-site technicians
  • Delivery managerThe whole delivery team, every region

Support and service

  • Service desk analystTakes incidents as they arrive and routes them
  • Network engineerPorts, VLANs and patching
  • Service manager, AVOwns the AV standard and its service
  • Service manager, networkOwns the network standard and its service

The Lab

  • Innovation engineerTests new kit before it ships

Leadership

  • Head of AV and ITThe whole service, every region

Partners

  • Integration vendorSees their own installations only
  • Service vendorRepairs under the service contract

Overview

  • EveryoneEvery role's first screen at once, to see the whole picture

Settings

Appearance
LookStudio
Text size
Default

Report

Tell the team

About 2.07 Flex desks A, Juneau office

Goes to Sofia Reyes, Service manager, AV. Reviewed within five working days.