1 Kramer PA-240Z amplifier
0 of 1 unit set up · nothing to reviewchecked just now
Setup is done by Aigna's engineers. Your installs are on the Deploy page.
Once for all 1
Through Device web interfaceSet on each unit by hand Device web interface. Keia Atlas cannot read these back, so a person confirms them.
3 settings to set and 6 to check; 0 left at the manufacturer's default.See every settingThe setup guide
The same on every unit
- High-Pass Filter
- On
The units
Only what differs per unit. Each unit's build sheet has every setting worked out.Nothing is ready for you here. Keia Atlas keeps checking these units.
| Unit | Hostname | Provision | Install | Configure | |
|---|---|---|---|---|---|
| Build sheet | dub-303-amp0110.20.3.59 | ||||
Setup order
Optional: tick as you go, or let the checks do it1Rack-mount PA-240Z and wire the ceiling speakers to the Hi-Z OUT terminal block.0/1
2Set DIP-switch 1 to Hi-Z and DIP-switch 2 to 70V or 100V before applying power.0/1
3Set the rear-panel master volume trimmer to a safe starting level.0/1
4Connect Ethernet, browse to the web pages, and change the default Admin/Admin login.0/1
5Set input mixing, EQ and the master volume/balance for the space from the Speaker Output page.0/1
6Confirm the space's audio (from the Poly Studio X bar or the switcher's audio out) reaches the speakers at the right level.0/1
7Firmware is applied by uploading a file on the Device Settings web page; there is no automatic-update option to turn off.0/1
Every setting
9 in the setup guide, as patternsValues marked Per unit are patterns here. Each unit's build sheet has them worked out: dub-303-amp01.
Output mode (DIP-switches)2
- Hi-Z/Lo-Z (DIP 1)Rear panel > Hi-Z/Lo-Z and 100V/70V DIP-switches > DIP 1Check it is Hi-Z (default)
Why
Aigna's Galil 6-C ceiling speakers are wired to the 70V/100V transformer taps, which needs Hi-Z mode; Lo-Z is only for a direct 4/8 ohm pair.
- 70V/100V (DIP 2)Rear panel > Hi-Z/Lo-Z and 100V/70V DIP-switches > DIP 2Check it is 100V (default)
Why
Matches Kramer's own default and the higher-voltage tap on the Galil 6-C, which keeps run current low over longer ceiling cable runs.
Network1
- DHCPDevice Settings > Ethernet SettingsCheck it is On, with a reservation on the AV VLAN
Why
Aigna's AV devices sit on a DHCP-reserved address on the AV VLAN rather than a hand-typed static one.
Security2
- Activate SecurityCheck it is Enabled (default)
Why
The web pages already prompt for a login out of the box; Aigna keeps it on.
- Web pages user name and passwordPer unitSet to From the password vault, per siteWorked out on the build sheet
Why
The default Admin/Admin login must be changed before the amplifier goes into service.
Audio3
- High-Pass FilterSet to On
Why
Cuts frequencies below 70Hz that the Galil 6-C isn't rated to reproduce, which saves amplifier headroom for a background-music/voice room.
- Bass/Mid/Treble EQCheck it is Flat (0dB), Kramer's default
Why
Left flat until a space's acoustics are measured; Aigna doesn't pre-set an EQ curve blind.
- Master VolumePer unitSet to Set per space during commissioningWorked out on the build sheet
Why
No factory default level is stated; it's set to a safe, audible level for each space's speaker count and ceiling height.
Firmware1
- Firmware update methodCheck it is Manual upload only, no automatic-update toggle exists
Why
There's nothing to turn off; firmware only changes when an installer manually uploads a file, which already matches Aigna's Lab-first policy.