Notes from the team
What's installed
16 devicesEach desk has
| Desk | Hub monitor | Second monitor, fed over DisplayPort from the hub monitor | Stage |
|---|---|---|---|
| Desk 01 | DEMO-DUB-000441AG-000441 | DEMO-DUB-000442AG-000442 | In service |
| Desk 02 | DEMO-DUB-000443AG-000443 | DEMO-DUB-000444AG-000444 | In service |
| Desk 03 | DEMO-DUB-000445AG-000445 | DEMO-DUB-000446AG-000446 | In service |
| Desk 04 | DEMO-DUB-000447AG-000447 | DEMO-DUB-000448AG-000448 | In service |
| Desk 05 | DEMO-DUB-000449AG-000449 | DEMO-DUB-000450AG-000450 | In service |
| Desk 06 | DEMO-DUB-000451AG-000451 | DEMO-DUB-000452AG-000452 | In service |
| Desk 07 | DEMO-DUB-000453AG-000453 | DEMO-DUB-000454AG-000454 | In service |
| Desk 08 | DEMO-DUB-000455AG-000455 | DEMO-DUB-000456AG-000456 | In service |
Compared against
Dual 27 inch: A 27 inch hub monitor plus a second 27 inch monitor daisy-chained from it.
- Required devices
- All recorded
- Wiring
- Checks pass
Lifecycle
- In service
- 16
Cable tests
Restricted: rack and switch portsAll 16 links passed certification · closest margin 3.1 dB · last tested 10 Oct 2026
| Link | Outlet | Cable | Length | Result | Margin | Tested |
|---|---|---|---|---|---|---|
| DUB-4.21-R1-U26-P14 | Desk 01/data/table top#1 | Cat6A | 24.86 m | Pass | 4.21 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P15 | Desk 01/data/table top#2 | Cat6A | 24.71 m | Pass | 3.19 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P16 | Desk 02/data/table top#1 | Cat6A | 26.5 m | Pass | 5.52 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P17 | Desk 02/data/table top#2 | Cat6A | 26.3 m | Pass | 5.93 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P18 | Desk 03/data/table top#1 | Cat6A | 24.93 m | Pass | 3.77 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P19 | Desk 03/data/table top#2 | Cat6A | 24.88 m | Pass | 3.70 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P20 | Desk 04/data/table top#1 | Cat6A | 26.3 m | Pass | 6.03 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P21 | Desk 04/data/table top#2 | Cat6A | 26.55 m | Pass | 5.21 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P22 | Desk 05/data/table top#1 | Cat6A | 21.6 m | Pass | 5.97 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P23 | Desk 05/data/table top#2 | Cat6A | 21.83 m | Pass | 5.75 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P24 | Desk 06/data/table top#1 | Cat6A | 23.3 m | Pass | 6.38 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P25 | Desk 06/data/table top#2 | Cat6A | 23.28 m | Pass | 3.64 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P26 | Desk 07/data/table top#1 | Cat6A | 21.68 m | Pass | 3.80 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P27 | Desk 07/data/table top#2 | Cat6A | 21.85 m | Pass | 3.15 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P28 | Desk 08/data/table top#1 | Cat6A | 23.34 m | Pass | 5.13 dB | 10 Oct 2026 |
| DUB-4.21-R1-U26-P29 | Desk 08/data/table top#2 | Cat6A | 23.33 m | Pass | 4.37 dB | 10 Oct 2026 |
From the cabling contractor's certification report, recorded on each run (made up for the demo). A margin under 3 dB passes but is worth a look.
Outlets
Per desk| Service | Where | How many | Serves | Provided by |
|---|---|---|---|---|
| Power | On the desk | 4 | monitor or dock, spare, spare, spare | IT |
| Data | On the desk | 2 | monitor or dock, spareOnly one is patched to a switch port. | IT |
Wiring
2 signal cables, 3 to outletsThe same at every desk.
List every cable
| Cable | From | To |
|---|---|---|
| Thunderbolt | Hub monitor, usb-c-2 | LaptopThunderbolt 4, 40 Gb/s, for two monitors |
| DisplayPort | Hub monitor, displayport-out-1 | Second monitor, fed over DisplayPort from the hub monitor, displayport-in-1Daisy chain |
| Cat 6 | Hub monitor, lan-1 | Data outlet 1, on the desk |
| Power | Hub monitor, power-in | Power outlet 1, on the desk |
| Power | Second monitor, fed over DisplayPort from the hub monitor, power-in | Power outlet 2, on the desk |