Keia Atlas

Vendor access

This part is for Aigna staff

Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.

Go to your installation

Module

Locations is switched off

Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.

Organisation settings

DesksNYCNew York office · Level 22In service

22.21 Flex desks F

All 16 units in service · no open incidentschecked just now

What's installed

16 devices
DeskMonitorStage
Desk 01DEMO-NYC-000924AG-000924In service
Desk 02DEMO-NYC-000925AG-000925In service
Desk 03DEMO-NYC-000926AG-000926In service
Desk 04DEMO-NYC-000927AG-000927In service
Desk 05DEMO-NYC-000928AG-000928In service
Desk 06DEMO-NYC-000929AG-000929In service
Desk 07DEMO-NYC-000930AG-000930In service
Desk 08DEMO-NYC-000931AG-000931In service
Desk 09DEMO-NYC-000932AG-000932In service
Desk 10DEMO-NYC-000933AG-000933In service
Desk 11DEMO-NYC-000934AG-000934In service
Desk 12DEMO-NYC-000935AG-000935In service
Desk 13DEMO-NYC-000936AG-000936In service
Desk 14DEMO-NYC-000937AG-000937In service
Desk 15DEMO-NYC-000938AG-000938In service
Desk 16DEMO-NYC-000939AG-000939In service

Incidents

No incidents recorded for this space.

All incidents at New York office

Compared against

Hot desk

Ultrawide 34 inch: A 34 inch monitor with a built-in dock: video, network and 90 W charging.

Required devices
All recorded
Wiring
Checks pass
Laptops
macOS, Windows

Lifecycle

In service
16

Cable tests

Restricted: rack and switch ports

All 32 links passed certification · closest margin 2.5 dB · last tested 6 Oct 2026

LinkOutletCableLengthResultMarginTested
NYC-22.22-R1-U26-P09Desk 01/data/table top#1Cat6A47.73 mPass5.62 dB6 Oct 2026
NYC-22.22-R1-U26-P10Desk 01/data/table top#2Cat6A47.61 mPass2.74 dB6 Oct 2026
NYC-22.22-R1-U26-P11Desk 02/data/table top#1Cat6A49.16 mPass4.74 dB6 Oct 2026
NYC-22.22-R1-U26-P12Desk 02/data/table top#2Cat6A49.19 mPass2.52 dB6 Oct 2026
NYC-22.22-R1-U26-P13Desk 03/data/table top#1Cat6A50.56 mPass3.42 dB6 Oct 2026
NYC-22.22-R1-U26-P14Desk 03/data/table top#2Cat6A50.65 mPass3.43 dB6 Oct 2026
NYC-22.22-R1-U26-P15Desk 04/data/table top#1Cat6A47.61 mPass5.95 dB6 Oct 2026
NYC-22.22-R1-U26-P16Desk 04/data/table top#2Cat6A47.51 mPass5.74 dB6 Oct 2026
NYC-22.22-R1-U26-P17Desk 05/data/table top#1Cat6A49.07 mPass4.73 dB6 Oct 2026
NYC-22.22-R1-U26-P18Desk 05/data/table top#2Cat6A49.2 mPass2.60 dB6 Oct 2026
NYC-22.22-R1-U26-P19Desk 06/data/table top#1Cat6A50.52 mPass2.83 dB6 Oct 2026
NYC-22.22-R1-U26-P20Desk 06/data/table top#2Cat6A50.57 mPass5.00 dB6 Oct 2026
NYC-22.22-R1-U26-P21Desk 07/data/table top#1Cat6A50.98 mPass6.43 dB6 Oct 2026
NYC-22.22-R1-U26-P22Desk 07/data/table top#2Cat6A51.05 mPass4.87 dB6 Oct 2026
NYC-22.22-R1-U26-P23Desk 08/data/table top#1Cat6A52.23 mPass3.26 dB6 Oct 2026
NYC-22.22-R1-U26-P24Desk 08/data/table top#2Cat6A52.34 mPass6.14 dB6 Oct 2026
NYC-22.22-R1-U26-P25Desk 09/data/table top#1Cat6A53.77 mPass5.71 dB6 Oct 2026
NYC-22.22-R1-U26-P26Desk 09/data/table top#2Cat6A54.04 mPass4.69 dB6 Oct 2026
NYC-22.22-R1-U26-P27Desk 10/data/table top#1Cat6A50.8 mPass4.99 dB6 Oct 2026
NYC-22.22-R1-U26-P28Desk 10/data/table top#2Cat6A50.77 mPass3.38 dB6 Oct 2026
NYC-22.22-R1-U26-P29Desk 11/data/table top#1Cat6A52.2 mPass3.35 dB6 Oct 2026
NYC-22.22-R1-U26-P30Desk 11/data/table top#2Cat6A52.45 mPass2.50 dB6 Oct 2026
NYC-22.22-R1-U26-P31Desk 12/data/table top#1Cat6A53.76 mPass4.84 dB6 Oct 2026
NYC-22.22-R1-U26-P32Desk 12/data/table top#2Cat6A54.03 mPass3.78 dB6 Oct 2026
NYC-22.22-R1-U26-P33Desk 13/data/table top#1Cat6A42.44 mPass2.85 dB6 Oct 2026
NYC-22.22-R1-U26-P34Desk 13/data/table top#2Cat6A42.26 mPass3.66 dB6 Oct 2026
NYC-22.22-R1-U26-P35Desk 14/data/table top#1Cat6A43.82 mPass4.73 dB6 Oct 2026
NYC-22.22-R1-U26-P36Desk 14/data/table top#2Cat6A44 mPass3.25 dB6 Oct 2026
NYC-22.22-R1-U26-P37Desk 15/data/table top#1Cat6A42.19 mPass3.61 dB6 Oct 2026
NYC-22.22-R1-U26-P38Desk 15/data/table top#2Cat6A42.1 mPass5.80 dB6 Oct 2026
NYC-22.22-R1-U26-P39Desk 16/data/table top#1Cat6A43.83 mPass5.85 dB6 Oct 2026
NYC-22.22-R1-U26-P40Desk 16/data/table top#2Cat6A43.72 mPass4.91 dB6 Oct 2026

From the cabling contractor's certification report, recorded on each run (made up for the demo). A margin under 3 dB passes but is worth a look.

Outlets

Per desk
ServiceWhereHow manyServesProvided by
PowerOn the desk4monitor or dock, spare, spare, spareIT
DataOn the desk2monitor or dock, spareOnly one is patched to a switch port.IT

Wiring

1 signal cable, 2 to outlets
USB

The same at every desk.

Where it startsWhere it endsThunderbolt: Monitor, usb-c-2 to LaptopMonitor, Dell UltraSharp 34 Curved Thunderbolt Hub Monitor (U3425WE)MonitorDell UltraSharp 34 Curved Thund…usb-c-2 · USB-CNetwork, on the desk #1Network, on the desk #1Power, on the desk #1Power, on the desk #1Laptop, The person's ownLaptopThe person's owncable
List every cable
CableFromTo
ThunderboltMonitor, usb-c-2LaptopOne cable: picture, network and charging
Cat 6Monitor, lan-1Data outlet 1, on the desk
PowerMonitor, power-inPower outlet 1, on the desk

View as

See Keia Atlas the way someone else does. A demo: nobody signs in.

Viewing asAnna ByrneAV and IT delivery engineer · EMEA

Suggested

Delivery

  • Delivery engineerDesigns and commissions spaces, from survey to handover
  • Project managerRuns projects day to day: dates, suppliers and who does what
  • On-site technicianInstalls and fixes kit in the offices
  • Programme managerPlans the year of projects across every region
  • Engineering managerLeads the delivery engineers
  • Project management leadLeads the project managers
  • On-site services managerLeads the on-site technicians
  • Delivery managerThe whole delivery team, every region

Support and service

  • Service desk analystTakes incidents as they arrive and routes them
  • Network engineerPorts, VLANs and patching
  • Service manager, AVOwns the AV standard and its service
  • Service manager, networkOwns the network standard and its service

The Lab

  • Innovation engineerTests new kit before it ships

Leadership

  • Head of AV and ITThe whole service, every region

Partners

  • Integration vendorSees their own installations only
  • Service vendorRepairs under the service contract

Overview

  • EveryoneEvery role's first screen at once, to see the whole picture

Settings

Appearance
LookStudio
Text size
Default

Report

Tell the team

About 22.21 Flex desks F, New York office

Goes to Sofia Reyes, Service manager, AV. Reviewed within five working days.