Keia Atlas

Vendor access

This part is for Aigna staff

Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.

Go to your installation

Module

Assets is switched off

Device types, units, models, setup guides, standards, IT stores and cables. This demo has the Assets module switched off in Organisation settings.

Organisation settings

SwitchMEL8.17 Comms room (MDF), Rack 1, U18Meraki dashboard · read 06:00Simulated

mel-817-as03

26 ports in use, each on the VLAN the plan gives itchecked just now

The ports

Cisco Catalyst 9300-48P · 50 ports
  • 10 Management
  • 20 Corporate
  • T Trunk: several VLANs, tagged
  • X 802.1X · M MAC check (MAB)
  • P Parked: patched, nothing plugged in
  • – Disabled: nothing patched

Restricted: rack and switch ports Recorded for the demo, as Meraki dashboard would report it. Select a port to open what is plugged into it.

Every port in use

26 in uses, 19 parked, 5 disabled
PortOn itModeVLANPlanChange
Port 1Nothing plugged in8.15 Flex desks A · Desk 9, Desk module A2 · Patch panel C port 1ShutParkedParked
Port 2Desk 10, Monitor8.15 Flex desks A · Desk 10, Desk module A1 · Patch panel C port 2Access802.1XPlanned VLAN 20 CorporateAs planned
Port 3Nothing plugged in8.15 Flex desks A · Desk 10, Desk module A2 · Patch panel C port 3ShutParkedParked
Port 4Desk 11, Monitor8.15 Flex desks A · Desk 11, Desk module A1 · Patch panel C port 4Access802.1XPlanned VLAN 20 CorporateAs planned
Port 5Nothing plugged in8.15 Flex desks A · Desk 11, Desk module A2 · Patch panel C port 5ShutParkedParked
Port 6Desk 12, Monitor8.15 Flex desks A · Desk 12, Desk module A1 · Patch panel C port 6Access802.1XPlanned VLAN 20 CorporateAs planned
Port 7Nothing plugged in8.15 Flex desks A · Desk 12, Desk module A2 · Patch panel C port 7ShutParkedParked
Port 8Desk 13, Monitor8.15 Flex desks A · Desk 13, Desk module A1 · Patch panel C port 8Access802.1XPlanned VLAN 20 CorporateAs planned
Port 9Nothing plugged in8.15 Flex desks A · Desk 13, Desk module A2 · Patch panel C port 9ShutParkedParked
Port 10Desk 14, Monitor8.15 Flex desks A · Desk 14, Desk module A1 · Patch panel C port 10Access802.1XPlanned VLAN 20 CorporateAs planned
Port 11Nothing plugged in8.15 Flex desks A · Desk 14, Desk module A2 · Patch panel C port 11ShutParkedParked
Port 12Desk 15, Monitor8.15 Flex desks A · Desk 15, Desk module A1 · Patch panel C port 12Access802.1XPlanned VLAN 20 CorporateAs planned
Port 13Nothing plugged in8.15 Flex desks A · Desk 15, Desk module A2 · Patch panel C port 13ShutParkedParked
Port 14Desk 16, Monitor8.15 Flex desks A · Desk 16, Desk module A1 · Patch panel C port 14Access802.1XPlanned VLAN 20 CorporateAs planned
Port 15Nothing plugged in8.15 Flex desks A · Desk 16, Desk module A2 · Patch panel C port 15ShutParkedParked
Port 16Desk 17, Monitor8.15 Flex desks A · Desk 17, Desk module A1 · Patch panel C port 16Access802.1XPlanned VLAN 20 CorporateAs planned
Port 17Nothing plugged in8.15 Flex desks A · Desk 17, Desk module A2 · Patch panel C port 17ShutParkedParked
Port 18Desk 18, Monitor8.15 Flex desks A · Desk 18, Desk module A1 · Patch panel C port 18Access802.1XPlanned VLAN 20 CorporateAs planned
Port 19Nothing plugged in8.15 Flex desks A · Desk 18, Desk module A2 · Patch panel C port 19ShutParkedParked
Port 20Desk 19, Monitor8.15 Flex desks A · Desk 19, Desk module A1 · Patch panel C port 20Access802.1XPlanned VLAN 20 CorporateAs planned
Port 21Nothing plugged in8.15 Flex desks A · Desk 19, Desk module A2 · Patch panel C port 21ShutParkedParked
Port 22Desk 20, Monitor8.15 Flex desks A · Desk 20, Desk module A1 · Patch panel C port 22Access802.1XPlanned VLAN 20 CorporateAs planned
Port 23Nothing plugged in8.15 Flex desks A · Desk 20, Desk module A2 · Patch panel C port 23ShutParkedParked
Port 24Desk 21, Monitor8.15 Flex desks A · Desk 21, Desk module A1 · Patch panel C port 24Access802.1XPlanned VLAN 20 CorporateAs planned
Port 25Nothing plugged in8.15 Flex desks A · Desk 21, Desk module A2 · Patch panel C port 25ShutParkedParked
Port 26Desk 22, Monitor8.15 Flex desks A · Desk 22, Desk module A1 · Patch panel C port 26Access802.1XPlanned VLAN 20 CorporateAs planned
Port 27Nothing plugged in8.15 Flex desks A · Desk 22, Desk module A2 · Patch panel C port 27ShutParkedParked
Port 28Desk 23, Monitor8.15 Flex desks A · Desk 23, Desk module A1 · Patch panel C port 28Access802.1XPlanned VLAN 20 CorporateAs planned
Port 29Nothing plugged in8.15 Flex desks A · Desk 23, Desk module A2 · Patch panel C port 29ShutParkedParked
Port 30Desk 24, Monitor8.15 Flex desks A · Desk 24, Desk module A1 · Patch panel C port 30Access802.1XPlanned VLAN 20 CorporateAs planned
Port 31Nothing plugged in8.15 Flex desks A · Desk 24, Desk module A2 · Patch panel C port 31ShutParkedParked
Port 32Desk 1, Adapter8.16 Flex desks B · Desk 1, Desk module A1 · Patch panel C port 32Access802.1XPlanned VLAN 20 CorporateAs planned
Port 33Nothing plugged in8.16 Flex desks B · Desk 1, Desk module A2 · Patch panel C port 33ShutParkedParked
Port 34Desk 2, Adapter8.16 Flex desks B · Desk 2, Desk module A1 · Patch panel C port 34Access802.1XPlanned VLAN 20 CorporateAs planned
Port 35Nothing plugged in8.16 Flex desks B · Desk 2, Desk module A2 · Patch panel C port 35ShutParkedParked
Port 36Desk 3, Adapter8.16 Flex desks B · Desk 3, Desk module A1 · Patch panel C port 36Access802.1XPlanned VLAN 20 CorporateAs planned
Port 37Nothing plugged in8.16 Flex desks B · Desk 3, Desk module A2 · Patch panel C port 37ShutParkedParked
Port 38Desk 4, Adapter8.16 Flex desks B · Desk 4, Desk module A1 · Patch panel C port 38Access802.1XPlanned VLAN 20 CorporateAs planned
Port 39Desk 5, Adapter8.16 Flex desks B · Desk 5, Desk module A1 · Patch panel C port 39Access802.1XPlanned VLAN 20 CorporateAs planned
Port 40Desk 6, Adapter8.16 Flex desks B · Desk 6, Desk module A1 · Patch panel C port 40Access802.1XPlanned VLAN 20 CorporateAs planned
Port 41Access point · mel-8-ap01Access point mel-8-ap01 · Ceiling jack above mel-8-ap01 · Patch panel C port 41Trunk, tagged 20, 90Planned VLAN 10 ManagementAs planned
Port 42Access point · mel-8-ap02Access point mel-8-ap02 · Ceiling jack above mel-8-ap02 · Patch panel C port 42Trunk, tagged 20, 90Planned VLAN 10 ManagementAs planned
Port 43Access point · mel-8-ap03Access point mel-8-ap03 · Ceiling jack above mel-8-ap03 · Patch panel C port 43Trunk, tagged 20, 90Planned VLAN 10 ManagementAs planned
Port 49Switch mel-817-cs01 port 3UplinkTrunk, tagged 20, 30, 31, 50, 60, 70, 90Planned VLAN 10 ManagementAs planned
Port 50Switch mel-817-cs02 port 3UplinkTrunk, tagged 20, 30, 31, 50, 60, 70, 90Planned VLAN 10 ManagementAs planned

Disabled, nothing patched: 44 to 48.

If this were off

Simulated

What this switch would cut off, worked out from the recorded patching. Press a port to narrow it.

Access switch 3, Level 8 Cisco Catalyst 9300-48P · Rack 1, U18 · 8.17 Comms room (MDF)

Would affect 2 spaces, no meetings in the next 24 hours and 2 services

  • Level 8

Would be affected: a projection, not a fault Keeps workingRestricted: floor plan
Its portsPressed ports are off; press one to keep it on and narrow the picture
4445464748UpUp

Restricted: rack and switch ports "Up" is an uplink: the way this switch reaches the internet.

Spaces it would cut off 2

As recorded

NetBox's names
The switch's record, with every interface's cable trace
id: mel-817-as03
rack: mel-8-17-r1
u: 18
platform: meraki
interfaces:
  - name: 1
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P01
  - name: 2
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P02
      device: AG-000566
      interface: lan-1
  - name: 3
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P03
  - name: 4
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P04
      device: AG-000567
      interface: lan-1
  - name: 5
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P05
  - name: 6
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P06
      device: AG-000568
      interface: lan-1
  - name: 7
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P07
  - name: 8
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P08
      device: AG-000569
      interface: lan-1
  - name: 9
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P09
  - name: 10
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P10
      device: AG-000570
      interface: lan-1
  - name: 11
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P11
  - name: 12
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P12
      device: AG-000571
      interface: lan-1
  - name: 13
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P13
  - name: 14
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P14
      device: AG-000572
      interface: lan-1
  - name: 15
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P15
  - name: 16
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P16
      device: AG-000573
      interface: lan-1
  - name: 17
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P17
  - name: 18
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P18
      device: AG-000574
      interface: lan-1
  - name: 19
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P19
  - name: 20
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P20
      device: AG-000575
      interface: lan-1
  - name: 21
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P21
  - name: 22
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P22
      device: AG-000576
      interface: lan-1
  - name: 23
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P23
  - name: 24
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P24
      device: AG-000577
      interface: lan-1
  - name: 25
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P25
  - name: 26
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P26
      device: AG-000578
      interface: lan-1
  - name: 27
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P27
  - name: 28
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P28
      device: AG-000579
      interface: lan-1
  - name: 29
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P29
  - name: 30
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P30
      device: AG-000580
      interface: lan-1
  - name: 31
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P31
  - name: 32
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P32
      device: AG-000582
      interface: lan-1
  - name: 33
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P33
  - name: 34
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P34
      device: AG-000584
      interface: lan-1
  - name: 35
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P35
  - name: 36
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P36
      device: AG-000586
      interface: lan-1
  - name: 37
    enabled: false
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P37
  - name: 38
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P38
      device: AG-000588
      interface: lan-1
  - name: 39
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P39
      device: AG-000590
      interface: lan-1
  - name: 40
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P40
      device: AG-000592
      interface: lan-1
  - name: 41
    enabled: true
    mode: tagged
    untagged_vlan: 10
    tagged_vlans:
      - 20
      - 90
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P41
      device: AG-003276
      interface: lan-1
  - name: 42
    enabled: true
    mode: tagged
    untagged_vlan: 10
    tagged_vlans:
      - 20
      - 90
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P42
      device: AG-003277
      interface: lan-1
  - name: 43
    enabled: true
    mode: tagged
    untagged_vlan: 10
    tagged_vlans:
      - 20
      - 90
    connected:
      cables:
        - mel-cb-12
        - MEL-8.17-R1-U12-P43
      device: AG-003278
      interface: lan-1
  - name: 49
    enabled: true
    mode: tagged
    untagged_vlan: 10
    tagged_vlans:
      - 20
      - 30
      - 31
      - 50
      - 60
      - 70
      - 90
    connected:
      cables:
        - mel-cb-17
      device: mel-817-cs01
      interface: 3
  - name: 50
    enabled: true
    mode: tagged
    untagged_vlan: 10
    tagged_vlans:
      - 20
      - 30
      - 31
      - 50
      - 60
      - 70
      - 90
    connected:
      cables:
        - mel-cb-18
      device: mel-817-cs02
      interface: 3
disabled: 44-48

View as

See Keia Atlas the way someone else does. A demo: nobody signs in.

Viewing asAnna ByrneAV and IT delivery engineer · EMEA

Suggested

Delivery

  • Delivery engineerDesigns and commissions spaces, from survey to handover
  • Project managerRuns projects day to day: dates, suppliers and who does what
  • On-site technicianInstalls and fixes kit in the offices
  • Programme managerPlans the year of projects across every region
  • Engineering managerLeads the delivery engineers
  • Project management leadLeads the project managers
  • On-site services managerLeads the on-site technicians
  • Delivery managerThe whole delivery team, every region

Support and service

  • Service desk analystTakes incidents as they arrive and routes them
  • Network engineerPorts, VLANs and patching
  • Service manager, AVOwns the AV standard and its service
  • Service manager, networkOwns the network standard and its service

The Lab

  • Innovation engineerTests new kit before it ships

Leadership

  • Head of AV and ITThe whole service, every region

Partners

  • Integration vendorSees their own installations only
  • Service vendorRepairs under the service contract

Overview

  • EveryoneEvery role's first screen at once, to see the whole picture

Settings

Appearance
LookStudio
Text size
Default

Report

Tell the team

About mel-817-as03, Melbourne office

Goes to Sofia Reyes, Service manager, AV. Reviewed within five working days.