Device types, units, models, setup guides, standards, IT stores and cables. This demo has the Assets module switched off in Organisation settings.
SwitchMEL8.17 Comms room (MDF), Rack 1, U18Meraki dashboard · read 06:00Simulated
mel-817-as03
26 ports in use, each on the VLAN the plan gives itchecked just now
The ports
Cisco Catalyst 9300-48P · 50 portsPorts 49 to 50 · uplinks
- 10 Management
- 20 Corporate
- T Trunk: several VLANs, tagged
- X 802.1X · M MAC check (MAB)
- P Parked: patched, nothing plugged in
- – Disabled: nothing patched
Restricted: rack and switch ports Recorded for the demo, as Meraki dashboard would report it. Select a port to open what is plugged into it.
Change VLAN
Every port in use
26 in uses, 19 parked, 5 disabled| Port | On it | Mode | VLAN | Plan | Change |
|---|---|---|---|---|---|
| Port 1 | Nothing plugged in8.15 Flex desks A · Desk 9, Desk module A2 · Patch panel C port 1 | Shut | Parked | Parked | |
| Port 2 | Desk 10, Monitor8.15 Flex desks A · Desk 10, Desk module A1 · Patch panel C port 2 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 3 | Nothing plugged in8.15 Flex desks A · Desk 10, Desk module A2 · Patch panel C port 3 | Shut | Parked | Parked | |
| Port 4 | Desk 11, Monitor8.15 Flex desks A · Desk 11, Desk module A1 · Patch panel C port 4 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 5 | Nothing plugged in8.15 Flex desks A · Desk 11, Desk module A2 · Patch panel C port 5 | Shut | Parked | Parked | |
| Port 6 | Desk 12, Monitor8.15 Flex desks A · Desk 12, Desk module A1 · Patch panel C port 6 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 7 | Nothing plugged in8.15 Flex desks A · Desk 12, Desk module A2 · Patch panel C port 7 | Shut | Parked | Parked | |
| Port 8 | Desk 13, Monitor8.15 Flex desks A · Desk 13, Desk module A1 · Patch panel C port 8 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 9 | Nothing plugged in8.15 Flex desks A · Desk 13, Desk module A2 · Patch panel C port 9 | Shut | Parked | Parked | |
| Port 10 | Desk 14, Monitor8.15 Flex desks A · Desk 14, Desk module A1 · Patch panel C port 10 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 11 | Nothing plugged in8.15 Flex desks A · Desk 14, Desk module A2 · Patch panel C port 11 | Shut | Parked | Parked | |
| Port 12 | Desk 15, Monitor8.15 Flex desks A · Desk 15, Desk module A1 · Patch panel C port 12 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 13 | Nothing plugged in8.15 Flex desks A · Desk 15, Desk module A2 · Patch panel C port 13 | Shut | Parked | Parked | |
| Port 14 | Desk 16, Monitor8.15 Flex desks A · Desk 16, Desk module A1 · Patch panel C port 14 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 15 | Nothing plugged in8.15 Flex desks A · Desk 16, Desk module A2 · Patch panel C port 15 | Shut | Parked | Parked | |
| Port 16 | Desk 17, Monitor8.15 Flex desks A · Desk 17, Desk module A1 · Patch panel C port 16 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 17 | Nothing plugged in8.15 Flex desks A · Desk 17, Desk module A2 · Patch panel C port 17 | Shut | Parked | Parked | |
| Port 18 | Desk 18, Monitor8.15 Flex desks A · Desk 18, Desk module A1 · Patch panel C port 18 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 19 | Nothing plugged in8.15 Flex desks A · Desk 18, Desk module A2 · Patch panel C port 19 | Shut | Parked | Parked | |
| Port 20 | Desk 19, Monitor8.15 Flex desks A · Desk 19, Desk module A1 · Patch panel C port 20 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 21 | Nothing plugged in8.15 Flex desks A · Desk 19, Desk module A2 · Patch panel C port 21 | Shut | Parked | Parked | |
| Port 22 | Desk 20, Monitor8.15 Flex desks A · Desk 20, Desk module A1 · Patch panel C port 22 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 23 | Nothing plugged in8.15 Flex desks A · Desk 20, Desk module A2 · Patch panel C port 23 | Shut | Parked | Parked | |
| Port 24 | Desk 21, Monitor8.15 Flex desks A · Desk 21, Desk module A1 · Patch panel C port 24 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 25 | Nothing plugged in8.15 Flex desks A · Desk 21, Desk module A2 · Patch panel C port 25 | Shut | Parked | Parked | |
| Port 26 | Desk 22, Monitor8.15 Flex desks A · Desk 22, Desk module A1 · Patch panel C port 26 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 27 | Nothing plugged in8.15 Flex desks A · Desk 22, Desk module A2 · Patch panel C port 27 | Shut | Parked | Parked | |
| Port 28 | Desk 23, Monitor8.15 Flex desks A · Desk 23, Desk module A1 · Patch panel C port 28 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 29 | Nothing plugged in8.15 Flex desks A · Desk 23, Desk module A2 · Patch panel C port 29 | Shut | Parked | Parked | |
| Port 30 | Desk 24, Monitor8.15 Flex desks A · Desk 24, Desk module A1 · Patch panel C port 30 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 31 | Nothing plugged in8.15 Flex desks A · Desk 24, Desk module A2 · Patch panel C port 31 | Shut | Parked | Parked | |
| Port 32 | Desk 1, Adapter8.16 Flex desks B · Desk 1, Desk module A1 · Patch panel C port 32 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 33 | Nothing plugged in8.16 Flex desks B · Desk 1, Desk module A2 · Patch panel C port 33 | Shut | Parked | Parked | |
| Port 34 | Desk 2, Adapter8.16 Flex desks B · Desk 2, Desk module A1 · Patch panel C port 34 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 35 | Nothing plugged in8.16 Flex desks B · Desk 2, Desk module A2 · Patch panel C port 35 | Shut | Parked | Parked | |
| Port 36 | Desk 3, Adapter8.16 Flex desks B · Desk 3, Desk module A1 · Patch panel C port 36 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 37 | Nothing plugged in8.16 Flex desks B · Desk 3, Desk module A2 · Patch panel C port 37 | Shut | Parked | Parked | |
| Port 38 | Desk 4, Adapter8.16 Flex desks B · Desk 4, Desk module A1 · Patch panel C port 38 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 39 | Desk 5, Adapter8.16 Flex desks B · Desk 5, Desk module A1 · Patch panel C port 39 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 40 | Desk 6, Adapter8.16 Flex desks B · Desk 6, Desk module A1 · Patch panel C port 40 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 41 | Access point · mel-8-ap01Access point mel-8-ap01 · Ceiling jack above mel-8-ap01 · Patch panel C port 41 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 42 | Access point · mel-8-ap02Access point mel-8-ap02 · Ceiling jack above mel-8-ap02 · Patch panel C port 42 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 43 | Access point · mel-8-ap03Access point mel-8-ap03 · Ceiling jack above mel-8-ap03 · Patch panel C port 43 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 49 | Switch mel-817-cs01 port 3Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned | |
| Port 50 | Switch mel-817-cs02 port 3Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned |
Disabled, nothing patched: 44 to 48.
If this were off
SimulatedWhat this switch would cut off, worked out from the recorded patching. Press a port to narrow it.
Access switch 3, Level 8 Cisco Catalyst 9300-48P · Rack 1, U18 · 8.17 Comms room (MDF)
Would affect 2 spaces, no meetings in the next 24 hours and 2 services
Level 8
Restricted: rack and switch ports "Up" is an uplink: the way this switch reaches the internet.
Spaces it would cut off 2
- 8.15 Flex desks AFloor 8 · 24 desks · 15 units
- 8.16 Flex desks BFloor 8 · 6 desks · 6 units
- Wi-Fi in the open areas3 access points
As recorded
NetBox's namesThe switch's record, with every interface's cable trace
id: mel-817-as03
rack: mel-8-17-r1
u: 18
platform: meraki
interfaces:
- name: 1
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P01
- name: 2
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P02
device: AG-000566
interface: lan-1
- name: 3
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P03
- name: 4
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P04
device: AG-000567
interface: lan-1
- name: 5
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P05
- name: 6
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P06
device: AG-000568
interface: lan-1
- name: 7
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P07
- name: 8
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P08
device: AG-000569
interface: lan-1
- name: 9
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P09
- name: 10
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P10
device: AG-000570
interface: lan-1
- name: 11
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P11
- name: 12
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P12
device: AG-000571
interface: lan-1
- name: 13
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P13
- name: 14
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P14
device: AG-000572
interface: lan-1
- name: 15
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P15
- name: 16
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P16
device: AG-000573
interface: lan-1
- name: 17
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P17
- name: 18
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P18
device: AG-000574
interface: lan-1
- name: 19
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P19
- name: 20
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P20
device: AG-000575
interface: lan-1
- name: 21
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P21
- name: 22
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P22
device: AG-000576
interface: lan-1
- name: 23
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P23
- name: 24
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P24
device: AG-000577
interface: lan-1
- name: 25
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P25
- name: 26
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P26
device: AG-000578
interface: lan-1
- name: 27
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P27
- name: 28
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P28
device: AG-000579
interface: lan-1
- name: 29
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P29
- name: 30
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P30
device: AG-000580
interface: lan-1
- name: 31
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P31
- name: 32
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P32
device: AG-000582
interface: lan-1
- name: 33
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P33
- name: 34
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P34
device: AG-000584
interface: lan-1
- name: 35
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P35
- name: 36
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P36
device: AG-000586
interface: lan-1
- name: 37
enabled: false
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P37
- name: 38
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P38
device: AG-000588
interface: lan-1
- name: 39
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P39
device: AG-000590
interface: lan-1
- name: 40
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P40
device: AG-000592
interface: lan-1
- name: 41
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P41
device: AG-003276
interface: lan-1
- name: 42
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P42
device: AG-003277
interface: lan-1
- name: 43
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- mel-cb-12
- MEL-8.17-R1-U12-P43
device: AG-003278
interface: lan-1
- name: 49
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- mel-cb-17
device: mel-817-cs01
interface: 3
- name: 50
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- mel-cb-18
device: mel-817-cs02
interface: 3
disabled: 44-48