Vendor access
This part is for Aigna staff
Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.
Go to your installationModule
Assets is switched off
Device types, units, models, setup guides, standards, IT stores and cables. This demo has the Assets module switched off in Organisation settings.
SwitchMEL8.17 Comms room (MDF), Rack 1, U23Meraki dashboard · read 06:00Simulated
mel-817-cs02
8 ports in use, each on the VLAN the plan gives itchecked just now
The ports
Cisco Catalyst 9500-24Y4C · 28 portsPorts 25 to 28 · uplinks
- 10 Management
- T Trunk: several VLANs, tagged
- P Parked: patched, nothing plugged in
- – Disabled: nothing patched
Restricted: rack and switch ports Recorded for the demo, as Meraki dashboard would report it. Select a port to open what is plugged into it.
Change VLAN
Every port in use
8 in uses, 0 parked, 20 disabled| Port | On it | Mode | VLAN | Plan | Change |
|---|---|---|---|---|---|
| Port 1 | Switch mel-817-as01 port 50Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned | |
| Port 2 | Switch mel-817-as02 port 50Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned | |
| Port 3 | Switch mel-817-as03 port 50Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned | |
| Port 4 | Switch mel-817-as04 port 50Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned | |
| Port 5 | Firewall BTrunk | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned | |
| Port 6 | Wireless controllerTrunk | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 25 | Switch mel-817-cs01 port 25Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned | |
| Port 26 | Switch mel-817-cs01 port 26Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned |
Disabled, nothing patched: 7 to 24, 27 to 28.
If this were off
SimulatedWhat this switch would cut off, worked out from the recorded patching. Press a port to narrow it.
Core switch B Cisco Catalyst 9500-24Y4C · Rack 1, U23 · 8.17 Comms room (MDF)
Would affect nothing: Core switch A carries every space
Level 8
Restricted: rack and switch ports "Up" is an uplink: the way this switch reaches the internet.
Spaces it would cut off 0
- None: Core switch A carries every space.
As recorded
NetBox's namesThe switch's record, with every interface's cable trace
id: mel-817-cs02
rack: mel-8-17-r1
u: 23
platform: meraki
interfaces:
- name: 1
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- mel-cb-14
device: mel-817-as01
interface: 50
- name: 2
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- mel-cb-16
device: mel-817-as02
interface: 50
- name: 3
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- mel-cb-18
device: mel-817-as03
interface: 50
- name: 4
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- mel-cb-20
device: mel-817-as04
interface: 50
- name: 5
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- mel-cb-23
device: AG-001599
- name: 6
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- mel-cb-29
rack: mel-8-17-r1
u: 29
- name: 25
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- mel-cb-21
device: mel-817-cs01
interface: 25
- name: 26
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- mel-cb-21
device: mel-817-cs01
interface: 26
disabled: 7-24,27-28