| Sized for | Needs | Has | Verdict |
|---|---|---|---|
| Data outlets | 129 18 spaces, 30 desks, 8 video rooms | 144 | 15 to spare |
| Access ports | 155 129 + 20% headroom | 192 | 37 to spare |
| Access switches | 4 48 ports each | 4 | Exactly enough |
| PoE budget | 232 W 12 devices as the vendors state; 9 PoE devices with no figure | – | Not recorded |
| Rack space | 42U 25U of parts + 25% growth | 42U | Exactly enough |
| UPS | Not sized load and runtime not recorded | APC Smart-UPS SRT 3000VA, 2U | Not checked |
Vendor access
This part is for Aigna staff
Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.
Go to your installationModule
Locations is switched off
Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.
OfficeMELAsia Pacific--:-- local · Simulated live
Melbourne office
1 space not working nowchecked just now
Health of each space now. Simulated.
- Meeting rooms
- Focus, huddle and offices
- Reception
- Pantry and café
- Print and storage
- Flex desks
- Breakout
- Corridors
- Stairs
- Lifts
- Toilets
- Riser
- Comms room
- Stores and ducts
Key Health
- WorkingNothing wrong now; shaded darker while in use
- Not working nowA unit offline or alerting, or an open incident
- ClosedOutside the office's hours; no ring
- FaultA P1 to P3 incident someone is on, or nobody has yet
- To reviewA P4, or a job waiting on something outside
- Work bookedA task or a device swap, no incident
- No open jobsNothing open in the space
- FaultA switch port serving the space is down or draws no power
- To reviewA switch port serving it is off the VLAN plan, or a cable passed its test with little margin
- FineEvery port up; its access point in service
- Not recordedNo switch port recorded for the space
- PlannedIn a project that has not reached the space yet
- Being installedThe new kit is going in now
- Snag openInstalled, with a snag still open
- Handed overDone and handed over
- CoveredA vendor covers the kit; the contract runs past 90 days
- To reviewThe covering contract ends within 90 days
- Not coveredNo vendor recorded for the kit
- Guides and fixesSetup guides or captured fixes cover the kit
- Known errorA manufacturer's known error affects a unit here
- Guide past dueA setup guide is past due for review (dashed)
- Nothing recordedNo guide, known error or captured fix yet
Replay
NowSimulated. Frames are drawn still; Play steps them one by one. Space pauses, ← and → step, Now goes back to live.
Internet
- Carrier OnePrimary · Dedicated internet access over fibre, handed off as Ethernet · 500 Mb/s symmetric
IT store
- 8.20 IT store7 spare units · 2 counted lines
- 2 below minimumLast counted 24 Sept 2026
Next two weeks
- Peregrine's table microphone cuts out during callsUntil 19 Oct · Incident
- Replace 6 devices due in 202619 Oct · Work plan
- Chase the console server backorder30 Oct · Project task
Spaces by floor
18 spacesAll 19 spaces in Spaces →Level 8 18 spaces
Comms rooms and racks
Cables at Melbourne office →Internet circuits
Restricted: internet circuits Follow them in 3DOne circuit: 500 Mb/s primary · Carrier One renews in 4 months
Carrier One
Primary500 Mb/s symmetric
- Circuit ID
- C1-MEL-0042491
- Service level
- 99.95% available, restored within 4 hours, 24/7
- Support
- Carrier One service desk, 24/7; account C1-ACC-40763
- Contract
- Renews in 4 months (21 Feb 2027), 36-month term
- Kind
- Dedicated internet access over fibre, handed off as Ethernet
Carrier details are demo values Demo value. The carrier's phone number is kept in the paging tool, not here.
Open work and incidents
Projects 1
- Melbourne office IDF switch refreshPRJ-19 · Comms room refresh · Procure
Incidents 1
- Peregrine's table microphone cuts out during callsP3 INC0041193 · In progress · 8.07 Peregrine
Vendors and visits
Vendors 1
- Brightwave IntegrationIntegration
Visits 0
No visits booked.
Hours and change window
Open 07:00 to 19:00, Monday to Friday · next change window Wednesday 21 Oct, 22:00 to 02:00
Office hours
07:00 to 19:00
Monday to Friday, Melbourne time. Displays and signage turn on at opening and off an hour after closing.
Hours and window are demo values Demo value.
Facts
- Kind
- Office
- Where
- Melbourne, Australia
- Region
- Asia Pacific
- Time zone
- Australia/Melbourne
- Floors
- Level 8
- Spaces
- 16 spaces, 30 desks, 1 comms room
- Devices
- 112 units
- Mains
- 230 V, 50 Hz, plug I
- On-site technician
- Ruby Chen
- 3D model
- Modelled: every floor, comms room, cable run and circuit