What it is for
Powers ceiling speakers and processes room audio for a codec. Used in Briefing auditorium · Large meeting room · Executive boardroom.
Installed by year
Ports
7 portsRear
Every port, in detail
| # | Port | Connector | Carries | Direction | Where |
|---|---|---|---|---|---|
| 1 | audio-in-1Unbalanced stereo audio input. | 3.5 mm | audio | In | Rear |
| 2 | audio-in-25-pin balanced stereo line-level input, up to +4dBu/10kOhm. | Terminal block | audio | In | Rear |
| 3 | audio-out-15-pin balanced stereo line-level output (e.g. to powered speakers). | Terminal block | audio | Out | Rear |
| 4 | lan-1LAN for IP control and embedded web pages. Under the REMOTE group label. | RJ45 | ethernet | Both ways | Rear |
| 5 | rs232-13-pin RS-232 control port. Under the REMOTE group label. | Terminal block | rs232 | Both ways | Rear |
| 6 | speaker-out-14-pin large terminal block. Lo-Z: stereo 2x120W into 4/8 ohm (L+ L-, R+ R-). Hi-Z: mono 1x240W 70V/100V using Hi-Z and COM pins. Mode set by adjacent DIP switches. | Terminal block | speaker level | Out | Rear |
| 7 | power-inFused AC mains inlet; separate POWER rocker switch to its right. Connector type inferred from the 3-pin inlet in the drawing; manual says only 'AC connector'. | IEC C14 | power | In | Rear |
Security support
Demo values- Firmware line
- Kramer PA-240Z firmware
- Security updates
- Until Jan 2029 Demo value
- Report a flaw
- The manufacturer publishes no page we could open (see gaps)
The manufacturer sets these dates; Keia Atlas tracks them and does not vouch for them. A warning shows from 12 months before support ends.
Spaces using it
5 spacesDUB 3.03 HeronDUB 5.02 BoardroomDUB 5.04 Briefing auditoriumNYC 20.04 HeronNYC 22.01 Corncrake
Space types that use it
5 units in 5 spaces at 2 officesNotes
- Kramer describes EQ, filters and input mixing rather than a full DSP.
- Half-rack width, 1U; two fit side by side with the RK-1 adapter.
What the manufacturer doesn't say
- Kramer publishes no vulnerability reporting page that could be opened on 30 Sept 2026, so security_support has no vulnerability_contact.
- Consumption is given only as 265 VA.
- The mains inlet type is read from the drawing, not named in text.
Sources
- PA-240Z Power Amplifier (1x240W @70V/100V & 2x120W @8 ohm) - Kramer
Specifications - PA-120Z / PA-240Z User Manual, P/N 2900-300802 Rev 6
Port labels, faces and panel layout - PA-120Z / PA-240Z Quick Start Guide
Port labels, faces and panel layout - Kramer PA-240Z product page (kramerav.com)
Specifications
Each model was read twice, independently, and the two readings reconciled against the manufacturer's text.