Notes from the team
What's installed
24 devicesEach desk has
| Desk | Monitor | Wired network through one of the display's USB-C ports | Stage |
|---|---|---|---|
| Desk 01 | DEMO-NYC-000817AG-000817 | DEMO-NYC-000818AG-000818 | In service |
| Desk 02 | DEMO-NYC-000819AG-000819 | DEMO-NYC-000820AG-000820 | In service |
| Desk 03 | DEMO-NYC-000821AG-000821 | DEMO-NYC-000822AG-000822 | In service |
| Desk 04 | DEMO-NYC-000823AG-000823 | DEMO-NYC-000824AG-000824 | In service |
| Desk 05 | DEMO-NYC-000825AG-000825 | DEMO-NYC-000826AG-000826 | In service |
| Desk 06 | DEMO-NYC-000827AG-000827 | DEMO-NYC-000828AG-000828 | In service |
| Desk 07 | DEMO-NYC-000829AG-000829 | DEMO-NYC-000830AG-000830 | In service |
| Desk 08 | DEMO-NYC-000831AG-000831 | DEMO-NYC-000832AG-000832 | In service |
| Desk 09 | DEMO-NYC-000833AG-000833 | DEMO-NYC-000834AG-000834 | In service |
| Desk 10 | DEMO-NYC-000835AG-000835 | DEMO-NYC-000836AG-000836 | In service |
| Desk 11 | DEMO-NYC-000837AG-000837 | DEMO-NYC-000838AG-000838 | In service |
| Desk 12 | DEMO-NYC-000839AG-000839 | DEMO-NYC-000840AG-000840 | In service |
Compared against
Mac: Apple Studio Display for Mac laptops, with a USB-C Ethernet adapter because the display has no network port.
- Required devices
- All recorded
- Wiring
- Checks pass
- Laptops
- macOS
Lifecycle
- In service
- 24
Cable tests
Restricted: rack and switch portsAll 24 links passed certification · closest margin 2.5 dB · last tested 6 Oct 2026
| Link | Outlet | Cable | Length | Result | Margin | Tested |
|---|---|---|---|---|---|---|
| NYC-21.23-R1-U22-P11 | Desk 01/data/table top#1 | Cat6A | 47.56 m | Pass | 4.70 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P12 | Desk 01/data/table top#2 | Cat6A | 47.89 m | Pass | 3.03 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P13 | Desk 02/data/table top#1 | Cat6A | 49.27 m | Pass | 3.00 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P14 | Desk 02/data/table top#2 | Cat6A | 49.36 m | Pass | 4.28 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P15 | Desk 03/data/table top#1 | Cat6A | 50.72 m | Pass | 5.54 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P16 | Desk 03/data/table top#2 | Cat6A | 50.79 m | Pass | 3.47 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P17 | Desk 04/data/table top#1 | Cat6A | 47.73 m | Pass | 2.66 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P18 | Desk 04/data/table top#2 | Cat6A | 47.8 m | Pass | 4.76 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P19 | Desk 05/data/table top#1 | Cat6A | 49.3 m | Pass | 5.70 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P20 | Desk 05/data/table top#2 | Cat6A | 49.41 m | Pass | 4.91 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P21 | Desk 06/data/table top#1 | Cat6A | 50.91 m | Pass | 3.39 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P22 | Desk 06/data/table top#2 | Cat6A | 50.73 m | Pass | 4.20 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P23 | Desk 07/data/table top#1 | Cat6A | 50.84 m | Pass | 5.98 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P24 | Desk 07/data/table top#2 | Cat6A | 51.01 m | Pass | 4.36 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P25 | Desk 08/data/table top#1 | Cat6A | 52.63 m | Pass | 3.37 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P26 | Desk 08/data/table top#2 | Cat6A | 52.42 m | Pass | 5.56 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P27 | Desk 09/data/table top#1 | Cat6A | 53.84 m | Pass | 2.95 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P28 | Desk 09/data/table top#2 | Cat6A | 53.89 m | Pass | 3.40 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P29 | Desk 10/data/table top#1 | Cat6A | 50.73 m | Pass | 3.62 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P30 | Desk 10/data/table top#2 | Cat6A | 50.87 m | Pass | 2.52 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P31 | Desk 11/data/table top#1 | Cat6A | 52.33 m | Pass | 5.81 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P32 | Desk 11/data/table top#2 | Cat6A | 52.4 m | Pass | 3.07 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P33 | Desk 12/data/table top#1 | Cat6A | 53.99 m | Pass | 3.11 dB | 6 Oct 2026 |
| NYC-21.23-R1-U22-P34 | Desk 12/data/table top#2 | Cat6A | 54.09 m | Pass | 3.25 dB | 6 Oct 2026 |
From the cabling contractor's certification report, recorded on each run (made up for the demo). A margin under 3 dB passes but is worth a look.
Outlets
Per desk| Service | Where | How many | Serves | Provided by |
|---|---|---|---|---|
| Power | On the desk | 4 | monitor or dock, spare, spare, spare | IT |
| Data | On the desk | 2 | monitor or dock, spareOnly one is patched to a switch port. | IT |
Wiring
2 signal cables, 1 to outletsThe same at every desk.
List every cable
| Cable | From | To |
|---|---|---|
| Thunderbolt | Monitor, usb-c-1 | LaptopThunderbolt 5: picture, camera and 96 W charging |
| USB-C | Wired network through one of the display's USB-C ports, usb-c-1 | Monitor, usb-c-3 |
| Cat 6 | Wired network through one of the display's USB-C ports, lan-1 | Data outlet 1, on the desk |