Vendor access
This part is for Aigna staff
Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.
Go to your installationModule
Assets is switched off
Device types, units, models, setup guides, standards, IT stores and cables. This demo has the Assets module switched off in Organisation settings.
SwitchCPH4.17 Comms room (MDF), Rack 1, U13Meraki dashboard · read 06:00Simulated
cph-417-as03
25 ports in use, each on the VLAN the plan gives itchecked just now
The ports
Cisco Catalyst 9300-48P · 50 portsPorts 49 to 50 · uplinks
- 10 Management
- 20 Corporate
- T Trunk: several VLANs, tagged
- X 802.1X · M MAC check (MAB)
- P Parked: patched, nothing plugged in
- – Disabled: nothing patched
Restricted: rack and switch ports Recorded for the demo, as Meraki dashboard would report it. Select a port to open what is plugged into it.
Change VLAN
Every port in use
25 in uses, 18 parked, 7 disabled| Port | On it | Mode | VLAN | Plan | Change |
|---|---|---|---|---|---|
| Port 1 | Nothing plugged in4.15 Flex desks A · Desk 8, Desk module A2 · Patch panel C port 1 | Shut | Parked | Parked | |
| Port 2 | Desk 9, Monitor4.15 Flex desks A · Desk 9, Desk module A1 · Patch panel C port 2 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 3 | Nothing plugged in4.15 Flex desks A · Desk 9, Desk module A2 · Patch panel C port 3 | Shut | Parked | Parked | |
| Port 4 | Desk 10, Monitor4.15 Flex desks A · Desk 10, Desk module A1 · Patch panel C port 4 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 5 | Nothing plugged in4.15 Flex desks A · Desk 10, Desk module A2 · Patch panel C port 5 | Shut | Parked | Parked | |
| Port 6 | Desk 11, Monitor4.15 Flex desks A · Desk 11, Desk module A1 · Patch panel C port 6 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 7 | Nothing plugged in4.15 Flex desks A · Desk 11, Desk module A2 · Patch panel C port 7 | Shut | Parked | Parked | |
| Port 8 | Desk 12, Monitor4.15 Flex desks A · Desk 12, Desk module A1 · Patch panel C port 8 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 9 | Nothing plugged in4.15 Flex desks A · Desk 12, Desk module A2 · Patch panel C port 9 | Shut | Parked | Parked | |
| Port 10 | Desk 13, Monitor4.15 Flex desks A · Desk 13, Desk module A1 · Patch panel C port 10 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 11 | Nothing plugged in4.15 Flex desks A · Desk 13, Desk module A2 · Patch panel C port 11 | Shut | Parked | Parked | |
| Port 12 | Desk 14, Monitor4.15 Flex desks A · Desk 14, Desk module A1 · Patch panel C port 12 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 13 | Nothing plugged in4.15 Flex desks A · Desk 14, Desk module A2 · Patch panel C port 13 | Shut | Parked | Parked | |
| Port 14 | Desk 15, Monitor4.15 Flex desks A · Desk 15, Desk module A1 · Patch panel C port 14 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 15 | Nothing plugged in4.15 Flex desks A · Desk 15, Desk module A2 · Patch panel C port 15 | Shut | Parked | Parked | |
| Port 16 | Desk 16, Monitor4.15 Flex desks A · Desk 16, Desk module A1 · Patch panel C port 16 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 17 | Nothing plugged in4.15 Flex desks A · Desk 16, Desk module A2 · Patch panel C port 17 | Shut | Parked | Parked | |
| Port 18 | Desk 17, Monitor4.15 Flex desks A · Desk 17, Desk module A1 · Patch panel C port 18 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 19 | Nothing plugged in4.15 Flex desks A · Desk 17, Desk module A2 · Patch panel C port 19 | Shut | Parked | Parked | |
| Port 20 | Desk 18, Monitor4.15 Flex desks A · Desk 18, Desk module A1 · Patch panel C port 20 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 21 | Nothing plugged in4.15 Flex desks A · Desk 18, Desk module A2 · Patch panel C port 21 | Shut | Parked | Parked | |
| Port 22 | Desk 19, Monitor4.15 Flex desks A · Desk 19, Desk module A1 · Patch panel C port 22 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 23 | Nothing plugged in4.15 Flex desks A · Desk 19, Desk module A2 · Patch panel C port 23 | Shut | Parked | Parked | |
| Port 24 | Desk 20, Monitor4.15 Flex desks A · Desk 20, Desk module A1 · Patch panel C port 24 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 25 | Nothing plugged in4.15 Flex desks A · Desk 20, Desk module A2 · Patch panel C port 25 | Shut | Parked | Parked | |
| Port 26 | Desk 1, Adapter4.16 Flex desks B · Desk 1, Desk module A1 · Patch panel C port 26 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 27 | Nothing plugged in4.16 Flex desks B · Desk 1, Desk module A2 · Patch panel C port 27 | Shut | Parked | Parked | |
| Port 28 | Desk 2, Adapter4.16 Flex desks B · Desk 2, Desk module A1 · Patch panel C port 28 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 29 | Nothing plugged in4.16 Flex desks B · Desk 2, Desk module A2 · Patch panel C port 29 | Shut | Parked | Parked | |
| Port 30 | Desk 3, Adapter4.16 Flex desks B · Desk 3, Desk module A1 · Patch panel C port 30 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 31 | Nothing plugged in4.16 Flex desks B · Desk 3, Desk module A2 · Patch panel C port 31 | Shut | Parked | Parked | |
| Port 32 | Desk 4, Adapter4.16 Flex desks B · Desk 4, Desk module A1 · Patch panel C port 32 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 33 | Nothing plugged in4.16 Flex desks B · Desk 4, Desk module A2 · Patch panel C port 33 | Shut | Parked | Parked | |
| Port 34 | Desk 5, Adapter4.16 Flex desks B · Desk 5, Desk module A1 · Patch panel C port 34 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 35 | Nothing plugged in4.16 Flex desks B · Desk 5, Desk module A2 · Patch panel C port 35 | Shut | Parked | Parked | |
| Port 36 | Desk 6, Adapter4.16 Flex desks B · Desk 6, Desk module A1 · Patch panel C port 36 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 37 | Desk 7, Adapter4.16 Flex desks B · Desk 7, Desk module A1 · Patch panel C port 37 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 38 | Desk 8, Adapter4.16 Flex desks B · Desk 8, Desk module A1 · Patch panel C port 38 | Access802.1X | Planned VLAN 20 Corporate | As planned | |
| Port 39 | Access point · cph-4-ap01Access point cph-4-ap01 · Ceiling jack above cph-4-ap01 · Patch panel C port 39 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 40 | Access point · cph-4-ap02Access point cph-4-ap02 · Ceiling jack above cph-4-ap02 · Patch panel C port 40 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 41 | Access point · cph-4-ap03Access point cph-4-ap03 · Ceiling jack above cph-4-ap03 · Patch panel C port 41 | Trunk, tagged 20, 90 | Planned VLAN 10 Management | As planned | |
| Port 49 | Switch cph-417-cs01 port 3Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned | |
| Port 50 | Switch cph-417-cs02 port 3Uplink | Trunk, tagged 20, 30, 31, 50, 60, 70, 90 | Planned VLAN 10 Management | As planned |
Disabled, nothing patched: 42 to 48.
If this were off
SimulatedWhat this switch would cut off, worked out from the recorded patching. Press a port to narrow it.
Access switch 3 Cisco Catalyst 9300-48P · Rack 1, U13 · 4.17 Comms room (MDF)
Would affect 2 spaces, no meetings in the next 24 hours and 2 services
Fourth floor
Restricted: rack and switch ports "Up" is an uplink: the way this switch reaches the internet.
Spaces it would cut off 2
- 4.15 Flex desks AFloor 4 · 20 desks · 12 units
- 4.16 Flex desks BFloor 4 · 8 desks · 8 units
- Wi-Fi in the open areas3 access points
As recorded
NetBox's namesThe switch's record, with every interface's cable trace
id: cph-417-as03
rack: cph-4-17-r1
u: 13
platform: meraki
interfaces:
- name: 1
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P01
- name: 2
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P02
device: AG-000247
interface: lan-1
- name: 3
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P03
- name: 4
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P04
device: AG-000248
interface: lan-1
- name: 5
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P05
- name: 6
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P06
device: AG-000249
interface: lan-1
- name: 7
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P07
- name: 8
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P08
device: AG-000250
interface: lan-1
- name: 9
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P09
- name: 10
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P10
device: AG-000251
interface: lan-1
- name: 11
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P11
- name: 12
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P12
device: AG-000252
interface: lan-1
- name: 13
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P13
- name: 14
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P14
device: AG-000253
interface: lan-1
- name: 15
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P15
- name: 16
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P16
device: AG-000254
interface: lan-1
- name: 17
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P17
- name: 18
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P18
device: AG-000255
interface: lan-1
- name: 19
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P19
- name: 20
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P20
device: AG-000256
interface: lan-1
- name: 21
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P21
- name: 22
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P22
device: AG-000257
interface: lan-1
- name: 23
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P23
- name: 24
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P24
device: AG-000258
interface: lan-1
- name: 25
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P25
- name: 26
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P26
device: AG-000260
interface: lan-1
- name: 27
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P27
- name: 28
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P28
device: AG-000262
interface: lan-1
- name: 29
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P29
- name: 30
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P30
device: AG-000264
interface: lan-1
- name: 31
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P31
- name: 32
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P32
device: AG-000266
interface: lan-1
- name: 33
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P33
- name: 34
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P34
device: AG-000268
interface: lan-1
- name: 35
enabled: false
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P35
- name: 36
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P36
device: AG-000270
interface: lan-1
- name: 37
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P37
device: AG-000272
interface: lan-1
- name: 38
enabled: true
mode: access
untagged_vlan: 20
auth: dot1x
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P38
device: AG-000274
interface: lan-1
- name: 39
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P39
device: AG-003283
interface: lan-1
- name: 40
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P40
device: AG-003284
interface: lan-1
- name: 41
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 90
connected:
cables:
- cph-cb-12
- CPH-4.17-R1-U14-P41
device: AG-003285
interface: lan-1
- name: 49
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- cph-cb-17
device: cph-417-cs01
interface: 3
- name: 50
enabled: true
mode: tagged
untagged_vlan: 10
tagged_vlans:
- 20
- 30
- 31
- 50
- 60
- 70
- 90
connected:
cables:
- cph-cb-18
device: cph-417-cs02
interface: 3
disabled: 42-48