Keia Atlas

Vendor access

This part is for Aigna staff

Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.

Go to your installation

Module

Assets is switched off

Device types, units, models, setup guides, standards, IT stores and cables. This demo has the Assets module switched off in Organisation settings.

Organisation settings

SwitchMEL8.17 Comms room (MDF), Rack 1, U17Meraki dashboard · read 06:00Simulated

mel-817-as02

28 ports in use, each on the VLAN the plan gives itchecked just now

The ports

Cisco Catalyst 9300-48P · 50 ports
  • 10 Management
  • 20 Corporate
  • 30 Room systems
  • 31 Displays and signage
  • 70 Printers
  • T Trunk: several VLANs, tagged
  • X 802.1X · M MAC check (MAB)
  • P Parked: patched, nothing plugged in
  • – Disabled: nothing patched

Restricted: rack and switch ports Recorded for the demo, as Meraki dashboard would report it. Select a port to open what is plugged into it.

Every port in use

28 in uses, 17 parked, 5 disabled
PortOn itModeVLANPlanChange
Port 1Display 1 · mel-808-dsp018.08 Barn Owl · Wall outlet A1 · Patch panel B port 1AccessMAC check (MAB)Planned VLAN 31 Displays and signageAs planned
Port 2In-room network switch · mel-808-sw018.08 Barn Owl · Wall outlet A2 · Patch panel B port 2Trunk, tagged 30Planned VLAN 10 ManagementAs planned
Port 3Nothing plugged in8.08 Barn Owl · Wall outlet A3 · Patch panel B port 3ShutParkedParked
Port 4Display 2 · mel-808-dsp028.08 Barn Owl · Wall outlet B4 · Patch panel B port 4AccessMAC check (MAB)Planned VLAN 31 Displays and signageAs planned
Port 5Video bar · mel-808-vc018.08 Barn Owl · Wall outlet B5 · Patch panel B port 5AccessMAC check (MAB)Planned VLAN 30 Room systemsAs planned
Port 6Touch controller · mel-808-tc018.08 Barn Owl · Floor box C1 · Patch panel B port 6AccessMAC check (MAB)Planned VLAN 30 Room systemsAs planned
Port 7Nothing plugged in8.08 Barn Owl · Floor box C2 · Patch panel B port 7ShutParkedParked
Port 8Scheduler panel · mel-808-sch018.08 Barn Owl · Wall outlet D1 · Patch panel B port 8AccessMAC check (MAB)Planned VLAN 30 Room systemsAs planned
Port 9Display · mel-809-dsp018.09 Wren · Wall outlet A1 · Patch panel B port 9AccessMAC check (MAB)Planned VLAN 31 Displays and signageAs planned
Port 10Video bar · mel-809-vc018.09 Wren · Wall outlet A2 · through the adapter · Patch panel B port 10AccessMAC check (MAB)Planned VLAN 30 Room systemsAs planned
Port 11Nothing plugged in8.09 Wren · Wall outlet A3 · Patch panel B port 11ShutParkedParked
Port 12Touch controller · mel-809-tc018.09 Wren · Wall outlet B1 · Patch panel B port 12AccessMAC check (MAB)Planned VLAN 30 Room systemsAs planned
Port 13Nothing plugged in8.09 Wren · Wall outlet B2 · Patch panel B port 13ShutParkedParked
Port 14Scheduler panel · mel-809-sch018.09 Wren · Wall outlet C1 · Patch panel B port 14AccessMAC check (MAB)Planned VLAN 30 Room systemsAs planned
Port 15Video bar · mel-810-vc018.10 Robin · Wall outlet A1 · Patch panel B port 15AccessMAC check (MAB)Planned VLAN 30 Room systemsAs planned
Port 16Display · mel-810-dsp018.10 Robin · Wall outlet A2 · Patch panel B port 16AccessMAC check (MAB)Planned VLAN 31 Displays and signageAs planned
Port 17Nothing plugged in8.10 Robin · Wall outlet A3 · Patch panel B port 17ShutParkedParked
Port 18Monitor8.11 Focus 8.11 · Desk module A1 · Patch panel B port 18Access802.1XPlanned VLAN 20 CorporateAs planned
Port 19Nothing plugged in8.11 Focus 8.11 · Desk module A2 · Patch panel B port 19ShutParkedParked
Port 20Monitor8.12 Focus 8.12 · Desk module A1 · Patch panel B port 20Access802.1XPlanned VLAN 20 CorporateAs planned
Port 21Nothing plugged in8.12 Focus 8.12 · Desk module A2 · Patch panel B port 21ShutParkedParked
Port 2234 inch monitor8.13 Office 8.13 · Wall outlet A1 · Patch panel B port 22Access802.1XPlanned VLAN 20 CorporateAs planned
Port 23Nothing plugged in8.13 Office 8.13 · Wall outlet A2 · Patch panel B port 23ShutParkedParked
Port 24Scheduler panel · mel-813-sch018.13 Office 8.13 · Wall outlet B1 · Patch panel B port 24AccessMAC check (MAB)Planned VLAN 30 Room systemsAs planned
Port 25Printer · mel-814-prn018.14 Copy and print · Wall outlet A1 · Patch panel B port 25AccessMAC check (MAB)Planned VLAN 70 PrintersAs planned
Port 26Nothing plugged in8.14 Copy and print · Wall outlet A2 · Patch panel B port 26ShutParkedParked
Port 27Desk 1, Monitor8.15 Flex desks A · Desk 1, Desk module A1 · Patch panel B port 27Access802.1XPlanned VLAN 20 CorporateAs planned
Port 28Nothing plugged in8.15 Flex desks A · Desk 1, Desk module A2 · Patch panel B port 28ShutParkedParked
Port 29Desk 2, Monitor8.15 Flex desks A · Desk 2, Desk module A1 · Patch panel B port 29Access802.1XPlanned VLAN 20 CorporateAs planned
Port 30Nothing plugged in8.15 Flex desks A · Desk 2, Desk module A2 · Patch panel B port 30ShutParkedParked
Port 31Desk 3, Monitor8.15 Flex desks A · Desk 3, Desk module A1 · Patch panel B port 31Access802.1XPlanned VLAN 20 CorporateAs planned
Port 32Nothing plugged in8.15 Flex desks A · Desk 3, Desk module A2 · Patch panel B port 32ShutParkedParked
Port 33Desk 4, Monitor8.15 Flex desks A · Desk 4, Desk module A1 · Patch panel B port 33Access802.1XPlanned VLAN 20 CorporateAs planned
Port 34Nothing plugged in8.15 Flex desks A · Desk 4, Desk module A2 · Patch panel B port 34ShutParkedParked
Port 35Desk 5, Monitor8.15 Flex desks A · Desk 5, Desk module A1 · Patch panel B port 35Access802.1XPlanned VLAN 20 CorporateAs planned
Port 36Nothing plugged in8.15 Flex desks A · Desk 5, Desk module A2 · Patch panel B port 36ShutParkedParked
Port 37Desk 6, Monitor8.15 Flex desks A · Desk 6, Desk module A1 · Patch panel B port 37Access802.1XPlanned VLAN 20 CorporateAs planned
Port 38Nothing plugged in8.15 Flex desks A · Desk 6, Desk module A2 · Patch panel B port 38ShutParkedParked
Port 39Desk 7, Monitor8.15 Flex desks A · Desk 7, Desk module A1 · Patch panel B port 39Access802.1XPlanned VLAN 20 CorporateAs planned
Port 40Nothing plugged in8.15 Flex desks A · Desk 7, Desk module A2 · Patch panel B port 40ShutParkedParked
Port 41Desk 8, Monitor8.15 Flex desks A · Desk 8, Desk module A1 · Patch panel B port 41Access802.1XPlanned VLAN 20 CorporateAs planned
Port 42Nothing plugged in8.15 Flex desks A · Desk 8, Desk module A2 · Patch panel B port 42ShutParkedParked
Port 43Desk 9, Monitor8.15 Flex desks A · Desk 9, Desk module A1 · Patch panel B port 43Access802.1XPlanned VLAN 20 CorporateAs planned
Port 49Switch mel-817-cs01 port 2UplinkTrunk, tagged 20, 30, 31, 50, 60, 70, 90Planned VLAN 10 ManagementAs planned
Port 50Switch mel-817-cs02 port 2UplinkTrunk, tagged 20, 30, 31, 50, 60, 70, 90Planned VLAN 10 ManagementAs planned

Disabled, nothing patched: 44 to 48.

If this were off

Simulated

What this switch would cut off, worked out from the recorded patching. Press a port to narrow it.

Access switch 2, Level 8 Cisco Catalyst 9300-48P · Rack 1, U17 · 8.17 Comms room (MDF)

Would affect 8 spaces, 19 meetings in the next 24 hours (64 people) and 2 services

  • Level 8

Would be affected: a projection, not a fault Keeps workingRestricted: floor plan
Its portsPressed ports are off; press one to keep it on and narrow the picture
4445464748UpUp

Restricted: rack and switch ports "Up" is an uplink: the way this switch reaches the internet.

Spaces it would cut off 8

As recorded

NetBox's names
The switch's record, with every interface's cable trace
id: mel-817-as02
rack: mel-8-17-r1
u: 17
platform: meraki
interfaces:
  - name: 1
    enabled: true
    mode: access
    untagged_vlan: 31
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P01
      device: AG-000530
      interface: lan-1
  - name: 2
    enabled: true
    mode: tagged
    untagged_vlan: 10
    tagged_vlans:
      - 30
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P02
      device: AG-000536
      interface: lan-9
  - name: 3
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P03
  - name: 4
    enabled: true
    mode: access
    untagged_vlan: 31
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P04
      device: AG-000531
      interface: lan-1
  - name: 5
    enabled: true
    mode: access
    untagged_vlan: 30
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P05
      device: AG-000532
      interface: lan-1
  - name: 6
    enabled: true
    mode: access
    untagged_vlan: 30
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P06
      device: AG-000533
      interface: lan-1
  - name: 7
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P07
  - name: 8
    enabled: true
    mode: access
    untagged_vlan: 30
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P08
      device: AG-000542
      interface: lan-1
  - name: 9
    enabled: true
    mode: access
    untagged_vlan: 31
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P09
      device: AG-000543
      interface: lan-1
  - name: 10
    enabled: true
    mode: access
    untagged_vlan: 30
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P10
      device: AG-000544
      interface: lan-1
  - name: 11
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P11
  - name: 12
    enabled: true
    mode: access
    untagged_vlan: 30
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P12
      device: AG-000545
      interface: lan-1
  - name: 13
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P13
  - name: 14
    enabled: true
    mode: access
    untagged_vlan: 30
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P14
      device: AG-000548
      interface: lan-1
  - name: 15
    enabled: true
    mode: access
    untagged_vlan: 30
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P15
      device: AG-000550
      interface: lan-1
  - name: 16
    enabled: true
    mode: access
    untagged_vlan: 31
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P16
      device: AG-000549
      interface: lan-1
  - name: 17
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P17
  - name: 18
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P18
      device: AG-000551
      interface: lan-1
  - name: 19
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P19
  - name: 20
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P20
      device: AG-000552
      interface: lan-1
  - name: 21
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P21
  - name: 22
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P22
      device: AG-000553
      interface: lan-1
  - name: 23
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P23
  - name: 24
    enabled: true
    mode: access
    untagged_vlan: 30
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P24
      device: AG-000555
      interface: lan-1
  - name: 25
    enabled: true
    mode: access
    untagged_vlan: 70
    auth: mab
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P25
      device: AG-000556
      interface: lan-1
  - name: 26
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P26
  - name: 27
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P27
      device: AG-000557
      interface: lan-1
  - name: 28
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P28
  - name: 29
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P29
      device: AG-000558
      interface: lan-1
  - name: 30
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P30
  - name: 31
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P31
      device: AG-000559
      interface: lan-1
  - name: 32
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P32
  - name: 33
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P33
      device: AG-000560
      interface: lan-1
  - name: 34
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P34
  - name: 35
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P35
      device: AG-000561
      interface: lan-1
  - name: 36
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P36
  - name: 37
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P37
      device: AG-000562
      interface: lan-1
  - name: 38
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P38
  - name: 39
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P39
      device: AG-000563
      interface: lan-1
  - name: 40
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P40
  - name: 41
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P41
      device: AG-000564
      interface: lan-1
  - name: 42
    enabled: false
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P42
  - name: 43
    enabled: true
    mode: access
    untagged_vlan: 20
    auth: dot1x
    connected:
      cables:
        - mel-cb-11
        - MEL-8.17-R1-U09-P43
      device: AG-000565
      interface: lan-1
  - name: 49
    enabled: true
    mode: tagged
    untagged_vlan: 10
    tagged_vlans:
      - 20
      - 30
      - 31
      - 50
      - 60
      - 70
      - 90
    connected:
      cables:
        - mel-cb-15
      device: mel-817-cs01
      interface: 2
  - name: 50
    enabled: true
    mode: tagged
    untagged_vlan: 10
    tagged_vlans:
      - 20
      - 30
      - 31
      - 50
      - 60
      - 70
      - 90
    connected:
      cables:
        - mel-cb-16
      device: mel-817-cs02
      interface: 2
disabled: 44-48

View as

See Keia Atlas the way someone else does. A demo: nobody signs in.

Viewing asAnna ByrneAV and IT delivery engineer · EMEA

Suggested

Delivery

  • Delivery engineerDesigns and commissions spaces, from survey to handover
  • Project managerRuns projects day to day: dates, suppliers and who does what
  • On-site technicianInstalls and fixes kit in the offices
  • Programme managerPlans the year of projects across every region
  • Engineering managerLeads the delivery engineers
  • Project management leadLeads the project managers
  • On-site services managerLeads the on-site technicians
  • Delivery managerThe whole delivery team, every region

Support and service

  • Service desk analystTakes incidents as they arrive and routes them
  • Network engineerPorts, VLANs and patching
  • Service manager, AVOwns the AV standard and its service
  • Service manager, networkOwns the network standard and its service

The Lab

  • Innovation engineerTests new kit before it ships

Leadership

  • Head of AV and ITThe whole service, every region

Partners

  • Integration vendorSees their own installations only
  • Service vendorRepairs under the service contract

Overview

  • EveryoneEvery role's first screen at once, to see the whole picture

Settings

Appearance
LookStudio
Text size
Default

Report

Tell the team

About mel-817-as02, Melbourne office

Goes to Sofia Reyes, Service manager, AV. Reviewed within five working days.