Keia Atlas

Vendor access

This part is for Aigna staff

Vendors see their own installation and the device reference they need to build it: device types, setup guides and models. Everything else stays with Aigna.

Go to your installation

Module

Locations is switched off

Regions, offices, floors and the spaces in them. This demo has the Locations module switched off in Organisation settings.

Organisation settings

OfficeNYCAmericas--:-- local ·  Simulated live

New York office

1 space not working nowchecked just now

Lens

Health of each space now. Simulated.

Touchdown and breakoutTown hall areaBreakoutBreakoutTouchdownSouth corridorNorth corridorWest linkEast linkStair ALift lobbyLifts 1 to 3Riser 1 (data)RiserCleaner's store and plantToilets and accessible toiletWCStair B (escape)StoreStoreStoreLockersStoreTown hall area20.01 Reception: 4.69 × 6.4 m (space type 6 × 5 m); Built the other way round; Door on the front wall, 2.99 to 4.39 m20.0120.02 Cafeteria: 14.06 × 6.4 m (space type 10 × 9 m); Built the other way round; Door on the front wall, 12.26 to 13.76 m20.0220.03 Pantry: 12.67 × 6.4 m (space type 10.5 × 7.96 m); Built the other way round; Door on the front wall, 0.3 to 1.7 m20.0320.04 Heron: 6.96 × 6.4 m (space type 4.6 × 9.7 m); Door on the front wall, 5.76 to 6.66 m20.0420.05 Curlew: 6.96 × 6.4 m (space type 4.6 × 9.7 m); Door on the front wall, 5.76 to 6.66 m20.0520.06 Gannet: 4.36 × 6.4 m (space type 3.66 × 7.62 m); Door on the front wall, 3.16 to 4.06 m20.0620.07 Kestrel: 4.62 × 6.4 m (space type 3.66 × 7.62 m); Door on the front wall, 3.42 to 4.32 m20.0720.08 Peregrine: 5.58 × 4 m (space type 3.66 × 6.1 m); Built the other way round; Door on the front wall, 0.3 to 1.2 m; A column on the long wall, boxed in20.0820.09 Barn Owl: 5.58 × 4 m (space type 3.66 × 6.1 m); Built the other way round; Door on the front wall, 0.3 to 1.2 m20.0920.10 Whooper Swan: 5.36 × 6.4 m (space type 6.6 × 5.2 m); Door on the front wall, 4.16 to 5.06 m20.1020.11 Oystercatcher: 3.63 × 6.4 m (space type 5.5 × 4.22 m); Door on the front wall, 2.43 to 3.33 m; A corner boxed in for a service riser20.1120.12 Lapwing: Door on the front wall, 1.87 to 2.75 m; A structural column by the window; A glass wall to the corridor: no wall plates on that side20.1220.13 Copy and print: Built the other way round; Door on the front wall, 0.3 to 1.18 m20.1320.14 Comms room (MDF): Door on the back wall, 2.6 to 3.5 m20.1420.30 IT store: Door on the front wall, 0.3 to 1.2 m20.30Ladder in the comms room: 95 cables of 407South corridor tray, west: 52 cables of 81South corridor tray, east: 39 cables of 54West link tray: 28 cables of 54East link tray: 31 cables of 54North corridor tray, west: 11 cables of 54North corridor tray, middle: 32 cables of 54North corridor tray, east: 16 cables of 54Branch to 20.01 Reception: 7 cables of 54Branch to 20.02 Cafeteria: 4 cables of 54Branch to 20.03 Pantry: 4 cables of 54Branch to 20.04 Heron: 17 cables of 54Branch to 20.05 Curlew: 7 cables of 54Branch to 20.06 Gannet: 7 cables of 54Branch to 20.07 Kestrel: 7 cables of 54Branch to 20.08 Peregrine: 7 cables of 54Branch to 20.09 Barn Owl: 7 cables of 54Branch to 20.10 Whooper Swan: 8 cables of 54Branch to 20.11 Oystercatcher: 7 cables of 54Branch to 20.12 Lapwing: 3 cables of 54Branch to 20.13 Copy and print: 2 cables of 54Branch to 20.30 IT store: 0 cables of 54Branch to access point nyc-20-ap01: 1 cables of 54Branch to access point nyc-20-ap02: 1 cables of 54Branch to access point nyc-20-ap03: 1 cables of 54Branch to access point nyc-20-ap04: 1 cables of 54Riser 1 (data)Rack 1nyc-20-ap01, U7 Pronyc-20-ap02, U7 Pronyc-20-ap03, U7 Pro Maxnyc-20-ap04, U7 Pro Max5 m
  • Meeting rooms
  • Reception
  • Pantry and café
  • Print and storage
  • Town hall
  • Breakout
  • Corridors
  • Stairs
  • Lifts
  • Toilets
  • Riser
  • Comms room
  • Stores and ducts
Restricted: floor plan Fictional floor plan: space sizes from the space types; layout, trays and cable lengths made up for the demo.
Key Health
  • WorkingNothing wrong now; shaded darker while in use
  • Not working nowA unit offline or alerting, or an open incident
  • ClosedOutside the office's hours; no ring

Internet

  • Carrier OnePrimary · Dedicated internet access over fibre, handed off as Ethernet · 2 Gb/s symmetric
  • Carrier TwoBackup · Dedicated internet access over fibre, handed off as Ethernet · 1 Gb/s symmetric
Circuit IDs and support ↓

Comms rooms

Racks and sizing ↓

IT store

Open the IT store →

Spaces by floor

60 spacesAll 63 spaces in Spaces →

Comms rooms and racks

Cables at New York office →
20.14 Comms room (MDF)Main comms room (MDF) · Rack 1, 42UUniFi standard
Sized forNeedsHasVerdict
Data outlets86 15 spaces, 8 video rooms; 1 space set per project9610 to spare
Access ports104 86 + 20% headroom14440 to spare
Access switches3 48 ports each3Exactly enough
PoE budget304 W 18 devices as the vendors state; 10 PoE devices with no figure2160 W1856 W to spare
Rack space42U 21U of parts + 25% growth42UExactly enough
UPSNot sized load and runtime not recordedAPC Smart-UPS SRT 3000VA, 2UNot checked
21.23 Comms room (IDF)Floor comms room (IDF) · Rack 1, 42UUniFi standard
Sized forNeedsHasVerdict
Data outlets212 23 spaces, 64 desks, 11 video rooms24028 to spare
Access ports255 212 + 20% headroom28833 to spare
Access switches6 48 ports each6Exactly enough
PoE budget476 W 20 devices as the vendors state; 9 PoE devices with no figure4320 W3844 W to spare
Rack space42U 28U of parts + 25% growth42UExactly enough
UPSNot sized load and runtime not recordedAPC Smart-UPS SRT 3000VA, 2UNot checked
22.22 Comms room (IDF)Floor comms room (IDF) · Rack 1, 42UUniFi standard
Sized forNeedsHasVerdict
Data outlets190 22 spaces, 56 desks, 9 video rooms; 1 space set per project1922 to spare
Access ports228 190 + 20% headroom24012 to spare
Access switches5 48 ports each5Exactly enough
PoE budget312 W 17 devices as the vendors state; 7 PoE devices with no figure3600 W3288 W to spare
Rack space42U 24U of parts + 25% growth42UExactly enough
UPSNot sized load and runtime not recordedAPC Smart-UPS SRT 3000VA, 2UNot checked

Internet circuits

Restricted: internet circuits Follow them in 3D

2 circuits: 2 Gb/s primary, 1 Gb/s backup · Carrier Two renews in 4 months

Carrier One

Primary

2 Gb/s symmetric

Circuit ID
C1-NYC-0040917
Service level
99.95% available, restored within 4 hours, 24/7
Support
Carrier One service desk, 24/7; account C1-ACC-40702
Contract
Renews 21 Jul 2027, 36-month term
Kind
Dedicated internet access over fibre, handed off as Ethernet

Carrier details are demo values Demo value. The carrier's phone number is kept in the paging tool, not here.

Carrier Two

Backup

1 Gb/s symmetric

Circuit ID
C2-NYC-0218836
Service level
99.9% available, restored within 8 hours, 24/7
Support
Carrier Two network operations centre, 24/7; account C2-ACC-88390
Contract
Renews in 4 months (21 Feb 2027), 24-month term
Kind
Dedicated internet access over fibre, handed off as Ethernet

Carrier details are demo values Demo value. The carrier's phone number is kept in the paging tool, not here.

Open work and incidents

Projects 1

Incidents 1

Vendors and visits

Vendors 1

Visits 0

No visits booked.

Hours and change window

Open 07:00 to 19:00, Monday to Friday · next change window tomorrow, 21:00 to 01:00

Office hours

07:00 to 19:00

Monday to Friday, New York time. Displays and signage turn on at opening and off an hour after closing.

Change window

21:00 to 01:00

Every Tuesday, running into the next morning. Firmware, switch and Wi-Fi changes that could interrupt a meeting happen here, as the network and Wi-Fi standards ask. Next: tomorrow, 21:00 to 01:00.

Hours and window are demo values Demo value.

Facts

Kind
Headquarters
Where
New York, United States
Region
Americas
Time zone
America/New_York
Floors
Level 20, Level 21, Level 22
Spaces
54 spaces, 120 desks, 3 comms rooms
Devices
395 units
Mains
120 V, 60 Hz, plug A, B
On-site technician
Carlos Mendes, Elena Vasquez
3D model
Modelled: every floor, comms room, cable run and circuit

View as

See Keia Atlas the way someone else does. A demo: nobody signs in.

Viewing asAnna ByrneAV and IT delivery engineer · EMEA

Suggested

Delivery

  • Delivery engineerDesigns and commissions spaces, from survey to handover
  • Project managerRuns projects day to day: dates, suppliers and who does what
  • On-site technicianInstalls and fixes kit in the offices
  • Programme managerPlans the year of projects across every region
  • Engineering managerLeads the delivery engineers
  • Project management leadLeads the project managers
  • On-site services managerLeads the on-site technicians
  • Delivery managerThe whole delivery team, every region

Support and service

  • Service desk analystTakes incidents as they arrive and routes them
  • Network engineerPorts, VLANs and patching
  • Service manager, AVOwns the AV standard and its service
  • Service manager, networkOwns the network standard and its service

The Lab

  • Innovation engineerTests new kit before it ships

Leadership

  • Head of AV and ITThe whole service, every region

Partners

  • Integration vendorSees their own installations only
  • Service vendorRepairs under the service contract

Overview

  • EveryoneEvery role's first screen at once, to see the whole picture

Settings

Appearance
LookStudio
Text size
Default

Report

Tell the team

About New York office

Goes to Sofia Reyes, Service manager, AV. Reviewed within five working days.